44
KX-TG7100BXS/KX-TG7100BXT/KX-TGA710CXS/KX-TGA710CXT
11 Measurements and Adjustments
11.1. The Setting Method of JIG (Base Unit)
11.1.1. Preparation
11.1.1.1. Equipment Required
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
• Frequency counter: it must be precise to be able to measure 1 Hz (precision; ±4 ppm).
Hewlett Packard, 53131A is recommended.
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope
11.1.1.2. JIG and PC
• EEPROM serial JIG
JIG Cable: PQZZ1CD300E*
• PC which runs in DOS mode
•
Batch file CD-ROM
for setting: PQZZTG7100BX
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300
and TCD500 series. (It is an upper compatible JIG Cable.)
11.1.2. PC Setting
11.1.2.1. Connections
Connect the AC adaptor to CN2 (base unit).
Connect the JIG Cable GND (black).
Connect the JIG Cable RX (red) and TX (yellow).
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω
)
New value (k
Ω
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
Summary of Contents for KX-TG7100BXS
Page 2: ...2 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT ...
Page 13: ...13 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 4 5 Signal Route ...
Page 19: ...19 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 7 4 For Service Hint ...
Page 22: ...22 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 8 1 2 Handset ...
Page 42: ...42 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 10 1 2 Handset ...
Page 43: ...43 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 10 2 How to Replace the Handset LCD ...
Page 58: ...58 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT Memo ...
Page 70: ...70 KX TG7100BXS KX TG7100BXT KX TGA710CXS KX TGA710CXT 15 3 Accessories and Packing Materials ...