background image

 

UX5000 Digital Terminal Mic Gain Adjustment Instructions

 

Before adjusting the gains on a digital terminal, adjustments must 

fi

rst be made to the analog trunks to be sure the levels are adequate. 

Adjusting only the terminal’s gain may have no affect if the trunks aren’t normalized 

fi

rst.

1.

Check the sidetone (volume) level on the analog trunks to be sure it’s at a good level.

2.

As required, in Program 14-01-02 and 14-01-03, make sure the entry for each required trunk is set to default (32).

3.

As required, use Program 81-07-01 to select the CODEC 

fi

lter setting for each trunk. (Though Program 81-07-01 is trunk 

based, if an entry of “4” is selected, the de

fi

nition for the 

fi

lter type de

fi

ned in Program 81-17-01 is used for all trunks 

de

fi

ned as type 4. Adjusting this setting too high could cause feedback in the handset. This step is a trial-and-error process. 

Start with the 

fi

lter type closest to the trunk’s level, test and readjust if needed.

 

Program 81-07-01

 

Default:

1

Entries:

0 = Filter type 0 (no 

fi

lter)

1 = Filter type 1 (600

 

Ω

 

 Line Loss 0dB (~500m from CO provider - high/loud from telco)

2 = Filter type 2 (600

 

Ω

 

 Line Loss 4dB (1-2km from CO provider - normal analog network)

3 = Filter type 3 (600

 

Ω

 

 Line Loss 8dB (3km from CO provider - low from telco)

4 = Filter type 4 (use Program 81-17 setting)

 

Program 81-17-01

 

Default:

0

Entries:

0 = None
1 = Type 5: 600

 

Ω

 

 Line Loss 2dB

2 = Type 6: 200

 

Ω

 

+ (100nF//680

 

Ω

 

)

 

 (not used in the U.S.)

 

3 = Type 7: 160

 

Ω

 

+ (150nF//1100

 

Ω

 

)

 

 (not used in the U.S.)

 

4 = Type 8: 900

 

Ω

 

4.

After changing the entry in Program 81-07-01, place a test call to check the volume level on the trunk and as a handsfree call.

5.

Program 14-01-02 can then be used to modify the dB level further, if needed.

 

Default:

32 (0dB)

Entries:

1~63 (-15.5 ~ +15.5dB in .5dB intervals)

 

The following procedures can be used, as needed to enhance the mic sensitivity transmit level of the UX5000 

 

Enhanced

 

 digital terminals 

once the analog trunk level has been set as directed above.

Section 1 - Check the Current Version of your Enhanced Digital Terminals
Section 2 - Adjusting the Mic Transmit Level
Section 3 - Adjusting the Full Duplex Parameter
Section 4 - Resetting Terminal Factory Default Values

 

Section 1 - Check the Current Version of Your Enhanced Digital Terminal

 

Use these steps to verify the current version of 

fi

rmware running on your Enhanced Digital Terminal. The procedure in 

 

Section 2 - 

Adjusting the Mic Transmit Level

 

 is intended to be used on terminal 

fi

rmware versions V1.80 and lower. If your terminal has 

V1.C0 or higher, the settings in 

 

Section 2

 

 and 

 

Section 3

 

 have already been applied. 

1.

Unplug the line cord from the back of the terminal.

2.

Press and hold both numeric keys 

 

*

 

 and 

 

#

 

.

3.

While holding the keys 

 

*

 

 and 

 

#

 

, plug the line cord back into the terminal.

4.

The LCD screen will display 

 

Initialize

 

.

5.

After 2 to 3 seconds, release keys * and # at the same time and the 

 

Terminal 

Information Menu

 

 will be displayed.

6.

Verify the Enhanced Digital Terminal 

fi

rmware version is V1.08 or lower 

before you proceed to 

 

Section 2 - Adjusting the Mic Transmit Level

 

 (V1.C0 and above will have the below values set from 

the factory).

Reviews: