2.2 Installing the Advanced Hybrid System
36
Installation Manual
2.2.8
Installing Surge Protector
Overview
A massive electrical surge can be caused if lightning strikes a telephone cable 10 m above ground,
or if a telephone line comes into contact with a power line. A surge protector is a device that is
connected to an outside (CO) line to prevent potentially dangerous electrical surges from entering the
building via the outside (CO) lines and damaging the PBX and connected equipment.
To protect the PBX from electrical surges, we strongly recommend connecting the PBX to a surge
protector that meets the following specifications:
–
Surge arrestor type: 3-electrode arrestor
–
DC spark-over voltage: 230 V
–
Maximum peak current: at least 10 kA
Additionally, proper earthing is very important for the protection of the PBX. (
→
2.2.5 Connecting
Frame Earth)
Many countries/areas have regulations requiring surge protection. Be sure to comply with all
applicable laws, regulations, and guidelines.
Installation
Extn.
Surge
Protector
Outside
(CO) Line
Terminal
Board
Outside
(CO) Line
PBX
Outside
(CO) Line
Extn.
Earth
Extn.
Frame Earth
SLT
PT
Extn.: Extension line