2.4 Fault Recovery/Diagnostics
Feature Guide
187
2.4
Fault Recovery/Diagnostics
2.4.1
Power Failure Transfer
Description
If the power supply to the PBX fails, outside (CO) line 1 will be automatically connected to extension jack 01
(
Power Failure Connections
). The PBX will switch from the current connections to Power Failure
Connections, and all existing conversations will be disconnected.
Only outside (CO) line calls handled by Power Failure Connections can be made during a power failure.
Conditions
•
We recommend connecting an SLT in parallel at extension jack 01, so that the SLT can be used during
a power failure.
Note that if the parallelled SLT is on an outside (CO) line call when the power is restored, that call will
be disconnected.
•
Only outside (CO) line calls are possible during a power failure. All other features will not function.
•
Automobile-type batteries, which must be user-supplied, can be connected as a system backup power
supply to operate all the features during a power failure.
The batteries can be connected directly to the unit with optional cables. For more information, refer to
the Installation Manual.
Installation Manual References
2.2.6 Connecting Backup Batteries
2.9 Power Failure Connections
Feature Guide References
1.10.9 Parallelled Telephone
Summary of Contents for KX-TEA308
Page 13: ...Feature Guide 13 Section 1 Call Handling Features...
Page 160: ...1 22 Audible Tone Features 160 Feature Guide...
Page 161: ...Feature Guide 161 Section 2 System Configuration and Administration Features...
Page 174: ...2 3 System Data Control 174 Feature Guide 3 2 PC Programming...
Page 189: ...Feature Guide 189 Section 3 Programming Instructions...
Page 261: ...Feature Guide 261 Section 4 Appendix...
Page 270: ...4 2 Tones Ring Tones 270 Feature Guide...
Page 271: ...Feature Guide 271 Index...
Page 277: ...Index Feature Guide 277...