Q
How do I set the queuing operation for an Incoming Call Distribution group?
A
•
Perform the following steps:
1.
On the
5.15 [3-5-2] Incoming Call Distribution Group—Queuing Time Table
screen, set the actions as required for each queuing table.
2.
On the
5.13 [3-5-1] Incoming Call Distribution Group—Group Settings
screen,
from the
Queuing Time Table
tab, select the number of the Queuing Time Table
to use in each time mode.
Q
How do I add an extension as a member of an Incoming Call Distribution (ICD) group?
A
•
Perform the following steps:
1.
On the
5.14 [3-5-1] Incoming Call Distribution Group—Group Settings—
Member List
screen, from the
Incoming Call Distribution
drop-down list, select
the group you want to modify.
The ICD group must have an extension number set.
2.
Enter the extension number of the extension you want to add in a blank cell of the
Extension Number
column.
3.
Set
Delayed Ring
as necessary.
4.
Click
Apply
.
Note that it is necessary to set the extension number of the ICD group in advance.
Q
I cannot set system speed dialling numbers from PC Console.
A
•
Set the COS of the extension to which PC Console is connected to Manager class, by
setting
Manager
on the
Extension Feature
tab of the
4.12 [2-7-1] Class of Service
—COS Settings
screen to "Enable".
•
System speed dialling numbers can only be edited by one PC Console at a time.
Q
I have set FWD through system programming, but calls are still not being forwarded.
A
•
Perform the following steps:
1.
Check that the
Call from CO—Present Button Status
or
Call from
Extension—Present Button Status
of the target extension on the
6.3 [4-1-2]
Wired Extension—FWD/DND
or
6.12 [4-2-2] Portable Station—FWD/DND
screen is set to "FWD".
2.
Create a FWD button on the target extension if one does not already exist.
3.
Press the FWD button so that it changes to FWD status.
PC Programming Manual
101
2.7.1 Frequently Asked Questions (FAQ)
Summary of Contents for KX-TDE100
Page 10: ...10 PC Programming Manual Table of Contents...
Page 14: ...Table 2 For CE model 14 PC Programming Manual 1 1 2 Entering Characters...
Page 15: ...Table 3 For RU model PC Programming Manual 15 1 1 2 Entering Characters...
Page 16: ...Table 4 For GR model 16 PC Programming Manual 1 1 2 Entering Characters...
Page 22: ...22 PC Programming Manual 1 2 2 Password Security...
Page 102: ...102 PC Programming Manual 2 7 1 Frequently Asked Questions FAQ...
Page 103: ...Section 3 1 Configuration PC Programming Manual 103...
Page 221: ...Feature Guide References None PC Programming Manual 221 3 24 1 1 Slot Port Property CSI F Port...
Page 435: ...Section 4 2 System PC Programming Manual 435...
Page 563: ...Section 5 3 Group PC Programming Manual 563...
Page 638: ...638 PC Programming Manual 5 28 3 10 Broadcasting Group Member List...
Page 639: ...Section 6 4 Extension PC Programming Manual 639...
Page 791: ...Section 7 5 Optional Device PC Programming Manual 791...
Page 818: ...818 PC Programming Manual 7 7 5 5 External Sensor...
Page 819: ...Section 8 6 Feature PC Programming Manual 819...
Page 839: ...Section 9 7 TRS PC Programming Manual 839...
Page 847: ...Section 10 8 ARS PC Programming Manual 847...
Page 859: ...Section 11 9 Private Network PC Programming Manual 859...
Page 872: ...872 PC Programming Manual 11 4 9 4 NDSS Key Table...
Page 873: ...Section 12 10 CO Incoming Call PC Programming Manual 873...
Page 902: ...902 PC Programming Manual 12 7 10 5 Miscellaneous...
Page 903: ...Section 13 11 Maintenance PC Programming Manual 903...
Page 933: ...Section 14 Appendix PC Programming Manual 933...
Page 981: ...PC Programming Manual 981 Notes...