1.16 S
Feature Manual
281
→
2.18.1 [11-1] Main—RS-232C—Communication—Stop Bit
→
[800] RS-232C Parameter—Stop Bit Length
•
If a call is transferred to an ICD group using Automatic Transfer, the condition code "TR" will not be
recorded on SMDR (
→
1.3.8 Call Transfer).
•
Host PBX Access Code
The dialed number including the Host PBX Access code will be recorded on SMDR only if the modified
number setting is selected in the ARS setting for SMDR.
•
When a Host PBX Access code is assigned to a trunk group, calls to extensions of the host PBX are
not recorded on SMDR.
•
A Host PBX Access Code can be used to record only long distance calls on SMDR when a CO line port
is connected directly to the telephone company (not a host PBX). This is allowed when the long
distance code (e.g., “0”) is assigned as the Host PBX Access code. All local calls (e.g., calls that do not
require a “0” to be dialed first) are treated as extensions of the telephone company and do not get
recorded on SMDR, because in this case this PBX recognizes the telephone company as the host PBX.
Therefore, only long distance calls are recorded on SMDR.
Installation Manual References
KX-TDA50
2.9.1 Connection of Peripherals
KX-TDA100/KX-TDA200
2.10.1 Connection of Peripherals
KX-TDA600
2.3.2 EMEC Card (KX-TDA6105)
2.13.1 Connection of Peripherals
Programming References
PC Programming Manual
2.9.4 [2-3] Timers & Counters—Dial / IRNA / Recall / Tone—Dial—Analog CO Call Duration Start
2.9.11 [2-7-1] Class of Service—COS Settings—CO & SMDR—Outgoing CO Call Printout (SMDR)
2.13.2 [6-2] Hotel—Main—SMDR for External Hotel Application 2—Printing Message 1–8
2.18.1 [11-1] Main
→
SMDR
→
SMDR Options
→
RS-232C—Communication—Baud Rate
→
RS-232C—Communication—NL Code
→
RS-232C—Communication—Word Length
→
RS-232C—Communication—Parity Bit
→
RS-232C—Communication—Stop Bit
PT Programming Manual
[800] RS-232C Parameter—New Line Code
[800] RS-232C Parameter—Baud Rate
[800] RS-232C Parameter—Word Length
[800] RS-232C Parameter—Parity Bit
[800] RS-232C Parameter—Stop Bit Length
[802] SMDR Page Length
Summary of Contents for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008...
Page 13: ...Feature Manual 13 Section 1 Features and Configurations ...
Page 183: ...1 11 M Feature Manual 183 Operating Manual References 1 3 43 Mute ...
Page 341: ...Feature Manual 341 Section 2 Appendix ...
Page 359: ...Feature Manual 359 Index ...
Page 364: ...Index 364 Feature Manual X XDP EXtra Device Port 95 XDP Digital 193 XDP Wireless 338 ...
Page 365: ...Index Feature Manual 365 ...