16 SLT Circuit Line Connection
Installing one unit to the system allows 16 single line telephones
(SLT’s) to be connected to jacks 09 through 16 for the KX-TD816,
or jacks 17 through 24 or jacks 25 through 32 for the KX-TD1232.
Installing two units allows 32 SLT’s to be connected to jacks 17
through 32 for the KX-TD1232.
This unit can be installed to any of the expansion areas provided on
the front of the system.
For unit installation, refer to the procedure “Section 2.4.4
“Installing Expansion Unit (KX-TD170/KX-TD180)” in the main
Installation Manual. Steps 1 through 5 and 7 through 10 of the
installation procedure are the same as the other expansion units.
Step 6 is different for each unit. Please note the following
instructions below instead of step 6 (Installation Manual) for this
unit.
Note
• System Programming [109] Expansion Unit Type is required for the
expansion unit location identification.
Installing Expansion Unit (KX-TD174)
Step 6
■
If the KX-TD174 is installed, use an Amphenol Connector to connect extensions.
Insert the connector into the jack.
P
an
as
on
ic
P
FT
po
rts
Connector type
Connector type
50-pin (Amphenol 57JE
series or the equivalent)
25
50
1
26
To 4-CO Line Unit KX-TD180
(Jack for Power Failure Transfer
†
)
KX-TD816 : Jacks 09 - 16
KX-TD1232 : Jacks 17 - 24 or 25 - 32
To extensions
2.4
Installation of Optional Cards and Units