Please read this manual before connecting the Digital Super Hybrid System.

Model No.  

KX-TD612CE

Digital Super Hybrid System

Installation Manual

Summary of Contents for KX-TD612CE

Page 1: ...Please read this manual before connecting the Digital Super Hybrid System Model No KX TD612CE Digital Super Hybrid System Installation Manual ...

Page 2: ...ice The Digital Proprietary Telephone is abbreviated as DPT The Single Line Telephone is abbreviated as SLT Console is a generic designation of Digital DSS Console KX T7240 KX T7440 and Digital Attendant Console KX T7441 This Installation Manual does not show the complete model number that indicates the country where your models should be used The model number of your unit is found on the label af...

Page 3: ...250 KX T7431 KX T7433 KX T7436 KX T7420 KX T7425 Console KX T7240 KX T7440 KX T7441 Digital DSS Console Digital DSS Console Digital Attendant Console Optional Equipment KX TD61280 KX TD61281 KX TD61291 KX TD61260 KX TD61261 KX T30865 KX A227 1 BRI Expansion Card Analogue CO Expansion Card Voice Message Card Doorphone Door Opener Card for T30865 Doorphone Door Opener Card for German type Doorphone ...

Page 4: ...alling Line Identification Presentation CLIP supplementary service ETS 300 093 Calling Line Identification Restriction CLIR supplementary service ETS 300 097 Connected Line Identification Presentation COLP supplementary service ETS 300 098 Connected Line Identification Restriction COLR supplementary service ETS 300 064 Direct Dialling In DDI supplementary service ETS 300 052 Multiple Subscriber Nu...

Page 5: ...WITH AN EARTHING CONTACT PLUG FOR SAFETY REASONS THIS PLUG MUST ONLY BE CONNECTED TO AN EARTHING CONTACT SOCKET WHICH HAS BEEN INSTALLED ACCORDING TO REGULATIONS THE POWER SUPPLY CORD IS USED AS THE MAIN DISCONNECT DEVICE ENSURE THAT THE SOCKET OUTLET IS LOCATED INSTALLED NEAR THE EQUIPMENT AND IS EASILY ACCESSIBLE TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE ...

Page 6: ...l with the RS 232C port of the unit You should note the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid in identification in the event of theft DATE OF PURCHASE NAME OF DEALER DEALER S ADDRESS DEALER S TEL NO For your future reference SERIAL NO MODEL NO ...

Page 7: ... and connection diagram Section 2 Installation Contains the basic system installation and wiring instructions as well as how to install the optional cards Section 3 Troubleshooting Provides information for the system and telephone troubleshooting Note The following documents may be used in conjunction with this manual Features Guide Programming Guide User Manual for KX TD612 System Digital Proprie...

Page 8: ...4 3 Extension Connection 38 2 4 4 EXtra Device Port XDP Parallelled Telephone Connection 41 2 4 5 Doorphone and Door Opener Connection 45 2 4 6 External Relay and Second Ringer Relay Connection 48 2 4 7 External Pager Paging Equipment Connection 50 2 4 8 External Music Source Connection 51 2 4 9 Printer and PC Connection 52 2 5 Optional Cards and Units Installation 55 2 5 1 Location of Optional Ca...

Page 9: ...on Manual 9 2 10 1 System Restart 76 2 11 System Data Clear 77 2 11 1 System Data Default Set 77 3 Troubleshooting 3 1 Troubleshooting 80 3 1 1 Installation 80 3 1 2 Connection 81 3 1 3 Operation 83 3 1 4 Using the Reset Button 84 ...

Page 10: ...Table of Contents 10 Installation Manual ...

Page 11: ...System Outline Installation Manual 11 Section 1 System Outline This section provides general information on the system including system capacity and connection diagram ...

Page 12: ... Network ISDN or the caller s identification number CLIP Built in Voice Message Enables you to store a voice message transferred from internal external calls if an optional card KX TD61291 is installed in the main unit KX TD612 Basic System Module Expansion Maximum Capacity CO line ISDN BRI CO Line Analogue CO Line Extension line 4 2 12 2 1 1 6 3 1 12 ISDN BRI port 2 and ISDN BRI port 3 can be sel...

Page 13: ...n jacks 1 to 4 in the system also supports a parallel connection of a digital proprietary telephone and a single line device They share the same extension number and are considered by the system to be 1 extension Super Hybrid System This system supports the connection of digital proprietary telephones consoles and single line devices such as single line telephones facsimiles Programming System The...

Page 14: ...System Outline 14 Installation Manual Uniform Call Distribution UCD Allows incoming calls to be distributed uniformly to a specific group of extensions ...

Page 15: ...ed with optional components or customer supplied peripherals such as external speakers external music sources e g radios and door openers To ISDN BRI port 1 2 initial To ISDN BRI port 3 additional Lightning Protectors 12 Extension lines Germantype Doorphone Door Openers External Music Source Amplifier Speaker Printer or Computer Single Line Telephone Cordless Phone Facsimile Doorphones KX T30865 V...

Page 16: ...s a display proprietary telephone Parallel connection of telephone is possible Refer to section 2 4 4 EXtra Device Port XDP Parallelled Telephone Connection Extension jacks 1 to 4 are available for eXtra Device Port XDP connection Extension jacks 5 to 8 are only for single line telephone ...

Page 17: ...3 1 1 1 1 1 Control Method Stored Programme Control ROM Control RAM MC68302 CPU 16 bit 14 7 MHz 40 Mbit Flash memory 8 Mbit SRAM Switching Non Blocking PCM Time Sharing Switch Power Supplies Primary Secondary 110 240 V AC 50 60 Hz Circuit Volt 5 V 26 V 15 V Internal Dialling Pulse 10 pps 20 pps Tone DTMF Connector ISDN BRI lines Extension Doorphone RJ45 Modular Connector 8 pin Terminal Block Termi...

Page 18: ...wer 110 240 V AC 50 60 Hz 58 W max When power is off by the power switch 1 2 W Backup Batteries Total voltage 24 V DC Maximum Current 2 3 A CentralOfficeLoop Limit 1 600 max Environmental Requirements 0 40 C 10 90 relative humidity no condensation Door Opener 60 V DC 1 A max 40 V AC 1 A max Second Ringer Relay 60 V DC 1 A max 40 V AC 1 A max External Relay 60 V DC 1 A max 40 V AC 1 A max Install t...

Page 19: ...System Outline Installation Manual 19 Class of Service 8 Hunting Group 32 Item Maximum Quantity ...

Page 20: ...System Outline 20 Installation Manual ...

Page 21: ...Installation Installation Manual 21 Section 2 Installation This section contains the basic system installation and wiring instructions as well as how to install the optional cards ...

Page 22: ...nd hot cold or humid places Temperature range 0 C 40 C 2 Sulfuric gases produced in areas where there are thermal springs etc may damage the equipment or contacts 3 Places in which shocks or vibrations are frequent or strong 4 Dusty places or places where water or oil may come into contact with the system 5 Near high frequency generating devices such as sewing machines or electric welders 6 On or ...

Page 23: ...ructure 7 Mis wiring may cause the system to operate improperly Refer to section 3 1 1 Installation and section 3 1 2 Connection 8 If an extension does not operate properly disconnect the telephone from the extension line and then connect again or turn off the power switch of the system and turn on again 9 The system is equipped with a 3 wire grounding type plug This is a safety feature If you are...

Page 24: ...on of the Main Unit 2 2 1 Unpacking Unpack the box and confirm the items below Main Unit 1 AC Cord 1 Screws for wall mounting 3 Washers for wall mounting 3 Pin Plug 2 8 pin Terminal Block for extensions 3 10 pin Terminal Block for external equipment 1 ...

Page 25: ...ns AC Inlet Power Switch Power Indicator Extension Connectors External Music Jack ISDN BRI Line Modular Jacks Serial Interface RS 232C Paging Jack Battery Interface Ground Terminal External Equipment Connector Serial Number K X T D 6 1 2 X X A B C 1 2 3 4 5 6 7 ...

Page 26: ... of the main unit If screws other than the ones supplied are used use the same sized diameter screws as the enclosed ones 2 ways of mounting are shown below Mounting on a Wooden Wall 1 Place the template on a wall to mark the screw positions 2 Install the screws and washers included into the wall 3 Hook the main unit on the screw heads Template Drive the screw to this position Wooden Wall ...

Page 27: ...all to mark the screw positions 2 Drill holes and drive the anchor plugs user supplied with a hammer flush to the wall 3 Install the screws included into the anchor plugs 4 Hook the main unit on the screw heads To the wall surface Anchor Plug Concrete Wall 29 mm 6 4 mm Drive the screw to this position ...

Page 28: ...proper grounding connection to the earth ground is very important to protect the system from the bad effect of external noise or to reduce the electric shock of a lightning strike The GND pin of the 3 pin type AC cable has an effect against the external noise or the lightning strikes but it may not be enough to protect the system A complete connection of the GND terminal of the PBX system to the e...

Page 29: ...00 included A When your contract is point to point B When your contract is point to multipoint B 1 Your system is at the end of the connection B 2 Your system is not at the end of the connection CAUTION Please consult your dealer to make a B 2 connection to remove TR on a printed circuit board PCB in your system To Central Office Network Termination Terminal Equipment 7 Terminal Equipment 1 To Cen...

Page 30: ...facsimiles or personal computers connected to the ISDN BRI ports port 2 and port 3 on the main unit KX TD612 A maximum of 8 ISDN extensions can be connected to each ISDN BRI port Be sure to place terminal resistor 600 at the end of the connection If the unit at the end of the connection has terminal resistor terminal resistor in another units should be removed To Central Office ISDN Extensions Net...

Page 31: ...inistered using a personal computer PC connected to a serial interface RS 232C port PC Connection Structure From Your KX TD612 to PC From PC to Your KX TD612 From Other KX TD612 to Your PC with ISDN card From Your PC with ISDN card to Other KX TD612 From Your KX TD612 to Other KX TD612 From Other KX TD612 to Your KX TD612 Computer Computer To Central Office Computer To Central Office ...

Page 32: ...en the screw 2 Remove the top front cover Closing the top front cover 1 Replace the covers and tighten the screws 2 Tie together all of the connected cords and attach them to the wall so that the cords cannot be pulled out of the system The screw is attached to the top front cover with a spring so that it will not be lost Top Front Cover Screw ...

Page 33: ...or CO lines or ISDN extension lines default Port 2 CO Port 3 Extension To use ISDN extension lines some System Programming and hardware changes are required beforehand A To make 4 CO lines 1 Insert the modular plugs of the ISDN BRI line cords 8 conductor wiring into the ISDN BRI ports 1 and 2 2 Connect the line cords to the terminal board or the modular jacks from the Central Office Wire Diameter ...

Page 34: ...se an internal power supply set the power supply jumper cover to the ON position as below b To use ISDN BRI ports as CO line ports set the power supply jumper cover to the OFF position 2 Insert the modular plugs of the ISDN BRI line cords 8 conductor wiring into the ISDN BRI ports 1 and 2 For CO line use EXT S0 1 3 1 3 1 3 1 3 SW503 SW502 SW500 SW501 For ISDN extension line use EXT S0 1 3 1 3 1 3 ...

Page 35: ... 2 Permanent Port 3 Call 424 ISDN Configuration Default Port 1 2 Point Port 3 Multipoint 425 ISDN Data Link Mode Default Port 1 2 Permanent Port 3 Call 426 ISDN TEI Mode Default Port 1 2 Fix 0 Port 3 Automatic Mis connection may cause the system to operate improperly See section 2 2 5 ISDN BRI CO Line Connection Structure and section 3 1 2 Connection To Terminal Board or Modular Jacks from the Cen...

Page 36: ...cable which is 10 m above ground can be as high as 200 000 volts This system should be installed with lightning protectors In addition grounding connection to earth ground is very important for the protection of the system Installation Diagram Outside Installation Diagram If you install an extension outside of the main building the following precautions are recommended 1 Install the extension wire...

Page 37: ...ample is only a recommendation The length of the earth rod and required depth depend on the composition of the soil 1 Installation location of the earth rod 2 Check obstructions 3 Composition of the earth rod 4 Depth of the earth rod 5 Size of the grounding wire Near the protector None Metal More than 50 cm Thickness is more than 1 6 mm CO Grounding Wire Underground Earth Rod System Lightning Prot...

Page 38: ...the system and the extension is as follows Wire Diameter of conductor Solid wire 0 4 0 6 mm Telephone Wiring Single line telephones 1 pair wire T R Digital proprietary telephones 2 pair wire L H T R If a telephone or answering machine with an A A1 relay is connected to the system set the A A1 relay switch of the telephone or answering machine to the OFF position Diameter 0 5 mm 0 6 mm Maximum leng...

Page 39: ...ephones 1 While pressing down on the hole at the top of the terminal block using a screwdriver insert the required telephone wire into the side hole as shown below 2 Attach the terminal blocks to the extension connectors on the system 1 Jack no 2 3 4 5 6 7 8 View of Extension Connector Jack 1 4 View of Extension Connector Jack 5 8 Jack X 1 Jack X 2 Jack X H High T Tip R Ring L Low T Tip R Ring To ...

Page 40: ...to the PBX main unit extension lines should be checked carefully If the extension lines are connected to the main unit with those wires making a short circuit between the H L pins or T R pins it may cause a malfunction of the system or may damage the circuit of the PBX system in the worst case ...

Page 41: ...n Any single line telephone can be connected in parallel with a digital proprietary telephone Three examples of the connections are shown below System programming is required to determine the type of connection Programming Reference 600 EXtra Device Port Feature Reference Extension Group Not only a single line telephone but a single line device such as an answering machine a facsimile or modem per...

Page 42: ...4 conductor wiring cord Connect pins T R H and L Back of the KX T7200 Series DPTs Connectors of the DPT outlets RJ11 To system To single line telephone HTRL TR Note Ensure the cords are inserted in the grooves to prevent damage to the connectors for both wall mounting and desktop positioning Back of the KX T7200 Series DPTs To system To single line telephone ...

Page 43: ...d 2 Connection through the Modular Socket Modular Socket 2 conductor wiring cord Connect pins T and R Digital Proprietary Telephone Single Line Telephone 4 conductor wiring cord Connect pins H and L only T and R are not required Modular Socket ...

Page 44: ...r T Adaptor Double Modular Socket 2 conductor wiring cord Connect pins T and R Digital Proprietary Telephone Single Line Telephone 4 conductor wiring cord For a digital proprietary telephone Connect pins H and L only T and R are not required Distribution Frame ...

Page 45: ...is as follows Installing the Doorphone 1 Loosen the screw to separate the doorphone into two halves 2 Attach the base cover to a wall using two screws Note Two kinds of screws are packed with KX T30865 Please choose the appropriate one for your wall type 3 Connect the wires from the main unit to the screws located in the front cover Diameter Maximum length 0 6 mm 180 m Panasonic Screw Screws Type ...

Page 46: ...t the top of the terminal block using a screwdriver insert the telephone wire into the side hole as shown below 2 Attach the terminal block to the external equipment connector on the system 3 Connect the line cords to the doorphone and door opener To the main unit To Doorphone and Door Opener Doorphone 1 Pin 1 and 2 Door Opener 1 Top View of External Equipment Connector Pin 9 and 10 ...

Page 47: ...Specifications for maximum current rating of the door opener contacts Programming Reference 122 Automatic Door Open Assignment 607 608 Doorphone Ringing Assignment Day Night Feature Reference Door Opener Doorphone Call Doorphone KX T30865 Panasonic To Door Opener ...

Page 48: ...12 documentation this second ringer is called Second Ringer Relay Never exceed the current ratings of the relay contacts Please see the current ratings in 1 3 1 Specifications Connection Use a 10 pin terminal block included for connection 1 While pressing down on the hole at the top of the terminal block using a screwdriver insert the equipment wire into the side hole as shown below 2 Attach the t...

Page 49: ...ay is activated Pin 5 Pin 3 becomes open and Pin 5 Pin 4 becomes closed Pin 6 Pin 7 is normally open It becomes closed when the ringer relay rings 3 Connect the equipment cables to the external relay and or second ringer relay Programming Reference 213 External Relay Connecting Time 512 External Relay Access Feature Reference External Relay Second Ringer ...

Page 50: ...dance 600 Length of cable 18 22 AWG Under 10 m Shielded cable is recommended To adjust the sound level of the pager use the volume control on the amplifier Programming Reference 804 External Pager BGM 805 External Pager Confirmation Tone 813 Floating Number Assignment Feature Reference Background Music BGM External Paging External Paging All Trunk CO Line Answer From Any Station TAFAS Speaker Ampl...

Page 51: ...pedance 8 Length of cable 18 22 AWG Under 10 m Shielded cable is recommended System programming for music sources used for Music on Hold and Background Music BGM is required To adjust the sound level of the Music on Hold use the volume control on the external music source Programming Reference 803 Music Source Use 804 External Pager BGM 990 System Additional Information Field 20 Feature Reference ...

Page 52: ...l Interface The cables must be shielded and the maximum length is 2 m Arrange the cables so that the printer or the PC will be connected to the system as shown in the chart on the following page The pin configuration of the Serial Interface RS 232C Connector is as follows Pin No Signal Name Circuit Type EIA CCITT 2 RD RXD Received Data BB 104 3 4 SD TXD ER DTR Transmitted Data Data Terminal Ready ...

Page 53: ...on Serial Interface RS 232C port on the system Serial Interface RS 232C port on the printer IBM PC Circuit Type EIA Signal Name Pin No Pin No Signal Name Circuit Type EIA BB RD RXD 2 BA SD TXD 3 CD ER DTR 4 AB SG 5 CC DR DSR 6 CA RS RTS 7 CB CS CTS 8 2 RD RXD BB 3 SD TXD BA 4 ER DTR CD 5 SG AB 6 DR DSR CC 7 RS RTS CA 8 CS CTS CB Serial Interface RS 232C port on the system Serial Interface RS 232C ...

Page 54: ... DR DSR input An ON condition of circuit DR DSR indicates the printer or the PC is ready Circuit DR DSR ON does not indicate that communication has been established with the printer or the PC Signal Ground SG Connects to the DC ground of the unit for all interface signals Data Terminal Ready ER DTR output This signal line is turned ON by the unit to indicate that it is ON LINE Circuit ER DTR ON do...

Page 55: ...ouch parts on the P boards in the main unit and on the optional cards If accessing the parts is required wear a grounding strap CAUTION Power off the system and unplug the AC cord before installing an optional card 1 BRI Expansion KX TD61280 Connector The front covers are open Optional Card Connector Voice Message Card KX TD61291 Connector Optional Doorphone Door Opener Card KX TD61260 or KX TD612...

Page 56: ...ttach the optional analogue CO expansion card KX TD61281 to the system and connect the cord to the connector then secure the screw as shown below Note Be sure to connect the cord that the length from the ferrite core is shorter than another side to the optional doorphone door opener card 4 Close the cover Optional Card Connector Optional Analogue CO Expansion Card KX TD61281 Screw Analogue CO Expa...

Page 57: ...7 Connection 1 While pressing down on the hole at the top of the terminal block included using a screw driver insert the required wire into the side hole as shown below 2 Attach the terminal blocks to nalogue CO expansion connector T R ...

Page 58: ...ansion Card KX TD61280 and Voice Message Card KX TD61291 can be installed in the system 4 When an BRI expansion card is installed set the jumper cover on the card to the appropriate position as shown below 1 Remove the 2 screws 2 Open the front cover 3 Attach the card holders to the optional card connectors Screws Front Cover ...

Page 59: ...ply set the power supply jumper cover to the ON position as below b To use the ISDN port as the CO line port set the power supply jumper cover to the OFF position For CO line use Jumper Cover EXT S0 1 3 1 3 1 3 1 3 For ISDN extension line use EXT S0 1 3 1 3 1 3 1 3 SW701 SW700 SW702 SW703 SW701 SW700 SW702 SW703 OR b View of Power supply jumper OFF ON 1 3 1 3 SW705 SW704 a View of Power supply jum...

Page 60: ...ramming Reference 820 OGM Recording Feature Reference Built in Voice Message CO Line Connection Assignment CO Line Connection Assignment Outgoing Direct Inward System Access DISA Intelligent Call Handling Distribution of Incoming Outside Calls Uniform Call Distribution UCD 1 BRI Expansion Card KX TD61280 Voice Message Card KX TD61291 ...

Page 61: ...O line 422 ISDN Port Type Default Port 1 2 CO Port 3 Extension 423 ISDN Layer 1 Active Mode Default Port 1 2 Permanent Port 3 Call 424 ISDN Configuration Default Port 1 2 Point Port 3 Multipoint 425 ISDN Data Link Mode Default Port 1 2 Permanent Port 3 Call 426 ISDN TEI Mode Default Port 1 2 Fix 0 Port 3 Automatic Extension line Default Setting Refer to section 2 4 1 CO Line Connection for the wir...

Page 62: ... system and connect the cord to the connector then secure the screw as shown below Note Be sure to connect the cord that the length from the ferrite core is shorter than another side to the optional doorphone door opener card 4 Close the cover Doorphone Door Opener Card Doorphone Door Opener German Type T30865 KX TD61260 Two 5 pin Connectors Not available 2 2 KX TD61261 Two 8 pin Connectors 2 Not ...

Page 63: ...crew driver insert the required wire into the side hole as shown below 2 Attach the terminal blocks to each doorphone door opener connector a KX TD61260 Two 5 pin Connectors KX TD61260 Two 5 pin terminal blocks No pin in the center KX TD61261 Two 8 pin terminal blocks Door Opener 2 Pin 4 and 5 Door Opener 3 Pin 4 and 5 Doorphone 2 Pin 1 and 2 Doorphone 3 Pin 1 and 2 ...

Page 64: ...r Microphone Shield German type Doorphone Doorphone 3 Adaptor 220V BL L O U B OV L O U B 12V 8V Door Opener 3 To RT TS2 TS1 b a TO1 TO2 German type Doorphone Doorphone 2 Adaptor 220V BL L O U B OV L O U B 12V 8V Door Opener 2 To RT TS2 TS1 b a TO1 TO2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 T0 Door Opener Connection Terminal TS Doorphone Current Supply Control Terminal b a Doorphone Call Path ...

Page 65: ...ly in the event of a power failure 1 Attach the cables KX A227 and 2 user supplied car batteries 12 VDC each as shown below Then insert the connector into the battery interface on the system Check the polarities of batteries and wire Make sure that you do not short the batteries and wires Fuse 250 V 3 15 A Two Car Batteries 12 VDC each Battery Interface Connector Red Black ...

Page 66: ... in the system The system will continue to be powered even if the power switch is turned OFF The power supply cord is used as the main disconnect device Make sure that the outlet is located installed near the equipment and is easily accessible 1 Set the system clear switch to the CLEAR position 2 Plug the AC power cord into the system and an AC outlet and turn on the unit 3 Press the reset button ...

Page 67: ...ith the default values If the system does not work properly see section 2 11 1 System Data Default Set After pressing the reset button return the system clear switch to the NORMAL position in step 3 while the power indicator is flashing Otherwise the system data will not be cleared ...

Page 68: ...quirements for installing TD612 PC programming software only CPU Pentium 133 MHz RAM 48 MB HDD 20 MB Recommendation of the ISDN cards for the remote maintenance FRITZ Card PCMCIA AVM FRITZ Card PCI AVM FRITZ Card classic AVM ELSA MicroLinkTM ISDN USB ELSA CreditCard ISDN Xircom Trademarks Microsoft Windows and Windows NT are registered trademarks of Microsoft Corporation in the United States and o...

Page 69: ...9 Installation Procedure 1 Start Windows 2 Insert the CD ROM included into CD ROM drive 3 Start Explorer and double click Setup exe in the PC PGM SW folder of the CD ROM 4 After exiting all Windows programmes on your computer click Next ...

Page 70: ...Manual 5 Click Yes after reading and accepting the license agreement If you choose No you cannot install the TD612 PC programming software 6 Select a folder to save the installed files Normally you do not need to change Click Next ...

Page 71: ...n Installation Manual 71 7 Choose a model a country and a language and then click Next 8 Select a programme folder where the software will be held Normally you do not need to change Click Next to start installing ...

Page 72: ...ete the installation 10 Start PC programming software which is in a pre assigned programme folder 11 Enter the password for the standard version which is TD612 and click OK When you start up the feature limited version just click OK without entering a password ...

Page 73: ...e start the procedure from Uninstall Start Program TD612PC or double clicking Setup exe which you started when installing and follow the directions Please do not attempt a different method of uninstalling the software For further information refer to Help of PC programming software and PC Programming page 11 15 in Getting Started manual ...

Page 74: ...ible to assign ISDN data automatically on PC programming software 1 Start PC programming software installed in your computer 2 Enter the password which is TD612 and then click OK 3 Click ISDN Config in Auto Config tool bar 4 Enter the password to connect with the main unit Default 1234 and then click OK 5 Click OK ...

Page 75: ...l be displayed Port Type 422 ISDN Port Type Layer 1 Active Mode 423 ISDN Layer 1 Active Mode Access Mode 424 ISDN Configuration Data Link Mode L2 425 ISDN Data Link Mode TEI Assign 426 ISDN TEI Mode If you entered unavailable number and failed in ISDN automatic configuration the assignments should be done manually For further information refer to Help of PC programming software ...

Page 76: ...ure again to confirm whether there definitely is a problem or not System Restart causes the following Camp on is cleared Calls on Hold are cancelled Calls on Exclusive Hold are cancelled Calls in progress are cancelled Call Park is cleared Other data is not cleared by System Restart 1 Turn the power switch OFF and then ON If the system still does not operate properly see section 2 11 1 System Data...

Page 77: ...n about 10 seconds return the system clear switch to the NORMAL position If successfully executed the DPTs should show the time as 0 00 CAUTION Before touching the system clear switch and reset button put on a grounding strap After pressing the reset button return the system clear switch to the NORMAL position in step 3 while the power indicator is flashing Otherwise the system data will not be cl...

Page 78: ...Installation 78 Installation Manual ...

Page 79: ...Troubleshooting Installation Manual 79 Section 3 Troubleshooting This section provides information for system and telephone troubleshooting ...

Page 80: ...ion Press the reset button Noise in external paging Noise on the wire between the system and the amplifier Use a shielded cable as the connection wire between the system and amplifier A short shielded cable is recommended Sound distortion from external music source Excessive input level from external music source Decrease the volume Speed Dialling or One Touch Dialling does not function Bad progra...

Page 81: ...e for T R and outer 2 wires are for H L Connection between the system and a single line telephone Use the correct cord The inner 2 wires are for T R Connection between the system and a single line telephone that is polarity sensitive Use the correct cord T R for T R CAUSE SOLUTION H T R L H T R L H T R L H T R L KX TD612 Extension KX TD612 Extension Example Example CAUSE SOLUTION H T R L T R H T R...

Page 82: ...is reversed Adjust the extension CO line socket as follows Jack 5 through 8 For SLT only If you cannot dial an extension Connection between the system and a single line telephone Use the correct cord T R is for T R CAUSE SOLUTION H T R L T R H T R L T R KX TD612 Extension KX TD612 Extension Example Example Extenison CO line 1 3 SW503 SW502 SW500 SW501 CAUSE SOLUTION T R T R H T R L T R T R H T R L...

Page 83: ...n Programming Handset Headset Selection When the headset is not being used select the HANDSET mode by Station Programming The unit does not ring The Ringer Volume Selector is set to OFF Set to HIGH or LOW When originating an outside call Call Transfer or Conference do not work The corresponding CO button does not exist on the digital proprietary telephone Program the CO button See 005 Flexible CO ...

Page 84: ... cleared by the following operation pressing the reset button and then setting the system clear switch to the NORMAL position while the power indicator is flashing within approximately 10 seconds Operation 1 If the system does not operate properly a Make sure that the system clear switch is set to the NORMAL position b Press the reset button 2 If the system still does not operate properly a Set th...

Page 85: ...Troubleshooting Installation Manual 85 e Set the system clear switch to the NORMAL position while the power indicator is flashing within approximately 10 seconds ...

Page 86: ...Troubleshooting 86 Installation Manual ...

Page 87: ... 1999 05 EC Radio and telecommunications terminal equipment directive Copyright This manual is copyrighted by Kyushu Matsushita Electric Co Ltd KME You may print out this manual solely for internal use with this model Except above you may not reproduce in any form in whole or part without the prior written consent of KME 2000 Kyushu Matsushita Electric Co Ltd All Rights Reserved KK0900EB0 ...