3.9.3 Starting Web Maintenance Console
System Requirements
For the system requirements of the PC (operating system, hardware specifications, supported browsers
etc.), refer to "3.9.3 Starting Web Maintenance Console" in the Programming Item List.
Copyright for MD5
This software uses the Source Code of RSA Data Security, Inc. described in the RFC1321 (MD5 Message-
Digest Algorithm).
Copyright (C) 1991-2, RSA Data Security, Inc. Created 1991. All rights reserved.
Licence to copy and use this software is granted provided that it is identified as the "RSA Data Security, Inc.
MD5 Message-Digest Algorithm" in all material mentioning or referencing this software or this function.
Licence is also granted to make and use derivative works provided that such works are identified as "de-
rived from the RSA Data Security, Inc. MD5 Message-Digest Algorithm" in all material mentioning or refer-
encing the derived work.
RSA Data Security, Inc. makes no representations concerning either the merchantability of this software or
the suitability of this software for any particular purpose. It is provided "as is" without express or implied war-
ranty of any kind.
These notices must be retained in any copies of any part of this documentation and/or software.
Connecting to Web Maintenance Console
1.
Connect the PC to the PBX:
•
Connect the PBX to a network with the LAN port and access the PBX from a PC in your LAN. For
details, refer to "3.9.2 PC Connection".
2.
Access Web Maintenance Console:
LAN
Connection: Launch your Web browser and input the IP address of the PBX followed by the Web
Maintenance Console port number into the address bar. The input method will differ according to the
PC’s connection to the PBX. The default IP address for the LAN port of the PBX is 192.168.0.101, and
the default Web Maintenance Console port number is 80. Accordingly, the address to enter to connect to
the PBX for the first time will be as follows (enter the address exactly as shown):
http://192.168.0.101
Note
•
The default subnet mask for the LAN port is 255.255.255.0.
Internet Connection (TLS Connection):
When the PC is accessing the PBX from a connection over the internet, the use of TLS is strongly rec-
ommended. When using a TLS encrypted connection, the default port is 443. The format of the address
to enter to connect to the PBX using a TLS encrypted connection will be as follows:
https://xxx.xxx.xxx.xxx:yyy
•
"xxx.xxx.xxx.xxx" is the IP address of a device that can be accessed from the Internet, such as the
IP address of a network router.
•
"yyy" is a port number. The network router’s port forwarding settings must be configured so that traf-
fic arriving at port "yyy" is forwarded to the correct IP address and port of the PBX in the LAN.
•
Port forwarding settings must specify the IP address and the port number of the network router
("xxx.xxx.xxx.xxx:yyy") to transfer the packets to the PBX in the LAN, so that the packets sent to the
global IP address and specified port of the router will be transferred to the IP address and specified
port of the PBX in the LAN.
•
Note the usage of "https" instead of "http".
•
If you connect to Web Maintenance Console using TLS, a security alert window is displayed. Follow
the prompts to install a security certificate. The procedure may vary according to your browser.
3.9.3 Starting Web Maintenance Console
82