60
KX-FT981LA-B / KX-FT987LA-B
573
Remote turn-on ring number set
×
number of
rings
00~99
10
Sets the number of rings before the unit starts to
receive a document in the TEL mode.
580
TAM continuous tone detection
(KX-FT987 only)
1: ON
2: OFF
1, 2
1
ON: Stops TAM operation when Dial tone, etc are
detected.
590
FAX auto redial time set
×
number of
times
00~99
02
Selects the number of redial times during FAX commu-
nication (not including the first dial).
591
FAX auto redial line disconnection time
set
×
second
001~999
065
Sets the FAX redial interval during FAX communication.
592
CNG transmit select
1: OFF
2: ALL
3: AUTO
1~3
2
Lets you select the CNG output during FAX transmis-
sion. ALL: CNG is output at phase A. AUTO: CNG id
output only when automatic dialing is performed. OFF:
CNG id not output at phase A. Refer to
Sometime
there is a transmit problem
(P.85).
593
Time between CED and 300bps
1: 75 msec
2: 500 msec
3: 1 sec
1~3
1
See
Symptom/Countermeasure Table
for long dis-
tance and international calls in
The unit can copy, but
cannot transmit/receive
(P.87). Refer to
Receive
Problem
(P.86) and
The unit can copy, but cannot
transmit/receive
(P.87).
594
Overseas DIS detection select
1: Detects at
the 1st time
2: Detects at
the 2nd time
1, 2
1
See
Symptom/Countermeasure Table
for long dis-
tance and international calls in
The unit can copy, but
cannot transmit/receive
(P.87). Refer to
Sometime
there is a transmit problem
(P.85) and
The unit can
copy, but cannot transmit/receive
(P.87).
595
Receive error limit value set
1: 5 %
2: 10 %
3: 15 %
4: 20 %
1~4
2
Sets the number of acceptable error lines when the
FAX reconstructs the received data. Refer to
Receive
Problem
(P.86).
596
Transmit level set
×
-1 dBm
00~15
11
Selects the FAX transmission level. Refer to
Sometime
there is a transmit problem
(P.85) and
Receive Prob-
lem
(P.86).
598
Receiving sensitivity
×
-1 dBm
20~48
42
Used when there is an error problem. Refer to
The unit
can copy, but the transmission and reception image
are incorrect
(P.90).
710
Memory clear except History data
Refer to
Memory Clear Specification
(P.61).
717
Transmit speed select
1: 9600 BPS
2: 7200 BPS
3: 4800 BPS
4: 2400 BPS
1~4
1
Adjusts the speed to start training during FAX transmis-
sion. Refer to
Sometime there is a transmit problem
(P.85) and
The unit can copy, but the transmission
and reception image are incorrect
(P.90).
718
Receive speed select
1: 9600 BPS
2: 7200 BPS
3: 4800 BPS
4: 2400 BPS
1~4
1
Adjusts the speed to start training during FAX recep-
tion. Refer to
Receive Problem
(P.86) and
The unit
can copy, but the transmission and reception image
are incorrect
(P.90).
722
Redial tone detect
1: ON
2: OFF
1, 2
2
Sets the tone detection mode after redialing.
763
CNG detect time for friendly reception
1: 10 sec
2: 20 sec
3: 30 sec
1~3
3
Selects the CNG detection tone of friendly reception.
773
DIS-DCS interval
1: 500 msec
2: 200 msec
1, 2
2
This is similar to #594. The time interval from receiving
DIS to sending DCS can be changed to wait for the
echo canceler to recover.
774
T4 timer
×
100 msec
00~99
00
Use this function when delay occurs in the line and
communication (ex. Mobile comm) does not work well.
784
Voice Prompt Test (KX-FT987 only)
See
Test Mode
(P.54).
815
Sensor test & Vox test (Vox test is available for KX-FT987 only.)
See
Test Mode
(P.54).
841
Digital SP-Phone check (KX-FT987 only)
See
Digital Speakerphone (KX-FT987 only)
(P.117).
845
Setting scanning density
00~32
00~32
08
Select scanning density when the code No.58 is set
“Normal”. If you want darker, select smaller value. If you
want fainter, select larger value. Refer to
Program
Mode Table
(P.93).
852
Print test pattern
See
Test Mode
(P.54).
853
Top margin
×
mm
1~9
5
----------
874
DTMF ON time
×
10 msec
06~20
10
----------
875
DTMF OFF time
×
10 msec
06~20
10
----------
Code
Function
Set Value
Effective
Range
Default
Remarks
Summary of Contents for KX-FT981LA-B
Page 11: ...11 KX FT981LA B KX FT987LA B 6 Technical Descriptions 6 1 Connection Diagram ...
Page 13: ...13 KX FT981LA B KX FT987LA B 6 2 1 General Block Diagram ...
Page 21: ...21 KX FT981LA B KX FT987LA B 6 4 2 Block Diagram ...
Page 23: ...23 KX FT981LA B KX FT987LA B ...
Page 63: ...63 KX FT981LA B KX FT987LA B 11 2 2 User Mode KX FT987 ...
Page 71: ...71 KX FT981LA B KX FT987LA B Countermeasure ...
Page 72: ...72 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 73: ...73 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 74: ...74 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 75: ...75 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 76: ...76 KX FT981LA B KX FT987LA B ...
Page 77: ...77 KX FT981LA B KX FT987LA B ...
Page 78: ...78 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 82: ...82 KX FT981LA B KX FT987LA B ...
Page 108: ...108 KX FT981LA B KX FT987LA B NG Wave pattern Note Refer to NG Example P 113 ...
Page 110: ...110 KX FT981LA B KX FT987LA B I O and Pin No Diagram ...
Page 113: ...113 KX FT981LA B KX FT987LA B 12 5 6 2 NG Example ...
Page 115: ...115 KX FT981LA B KX FT987LA B ...
Page 120: ...120 KX FT981LA B KX FT987LA B 12 5 9 2 Troubleshooting Flow Chart ...
Page 126: ...126 KX FT981LA B KX FT987LA B 12 5 13 Thermal Head Section Refer to Thermal Head P 22 ...
Page 127: ...127 KX FT981LA B KX FT987LA B 13 Service Fixture Tools ...
Page 130: ...130 KX FT981LA B KX FT987LA B 14 1 2 How to Remove the Cutter Unit KX FT987 only ...
Page 131: ...131 KX FT981LA B KX FT987LA B 14 1 3 How to Remove the Lock Lever and Thermal Head ...
Page 133: ...133 KX FT981LA B KX FT987LA B 14 2 2 How to Remove the P C Boards and Power Cord ...
Page 136: ...136 KX FT981LA B KX FT987LA B 14 3 2 How to Remove the Operation Board LCD and Platen Roller ...
Page 137: ...137 KX FT981LA B KX FT987LA B 14 3 3 How to Remove the Separation Rubber Flap ...
Page 138: ...138 KX FT981LA B KX FT987LA B 14 4 Installation Position of the Lead Wires ...
Page 139: ...139 KX FT981LA B KX FT987LA B ...
Page 147: ...147 KX FT981LA B KX FT987LA B 15 2 3 4 Copying REFERENCE Sensor Section P 123 ...
Page 152: ...152 KX FT981LA B KX FT987LA B 16 1 4 Power Supply Board ...
Page 154: ...154 KX FT981LA B KX FT987LA B 16 3 Test Chart 16 3 1 ITU T No 1 Test Chart ...
Page 155: ...155 KX FT981LA B KX FT987LA B 16 3 2 ITU T No 2 Test Chart ...
Page 168: ...168 KX FT981LA B KX FT987LA B MEMO ...
Page 178: ...178 KX FT981LA B KX FT987LA B 20 1 1 Operation Panel Section KX FT981 ...
Page 179: ...179 KX FT981LA B KX FT987LA B 20 1 2 Operation Panel Section KX FT987 ...
Page 180: ...180 KX FT981LA B KX FT987LA B 20 1 3 Upper Cabinet Section ...
Page 181: ...181 KX FT981LA B KX FT987LA B 20 1 4 Lower Cabinet Section ...
Page 182: ...182 KX FT981LA B KX FT987LA B 20 1 5 Gear Block Section ...
Page 183: ...183 KX FT981LA B KX FT987LA B 20 1 6 Screws ...
Page 184: ...184 KX FT981LA B KX FT987LA B 20 1 7 Accessories and Packing Materials ...
Page 192: ...192 KX FT981LA B KX FT987LA B K N KXFT981LAB KXFT987LAB ...