31
KX-FT981LA-B / KX-FT987LA-B
3.
Facsimile Call Time Series
As shown in the following diagram, the facsimile call time series is divided into five phases.
Phase A
: Call setting
Call setting can be manual/automatic.
Phase B
: Pre-message procedure
Phase B is a pre-processing procedure and sequence for confirming the status of the terminal, transmission route, etc., and for
terminal control. It implements terminal preparation status, determines and displays terminal constants, confirms synchroniza-
tion status, etc. and prepares for transmission of facsimile messages.
Phase C
: Message transmission
Phase C is the procedure for the transmitting facsimile messages.
Phase D
: Post message procedure
Phase D is the procedure for confirming that the message is completed and received. For continuous transmission, phase B or
phase C is repeated for transmission.
Phase E
: Call retrieval
Phase E is the procedure for call retrieval, that is for circuit disconnection.
4.
Concerning Transmission Time
Transmission Time = Control Time + Image Transmission Time + Hold Time
Transmission time consists of the following.
Control time:
This is time at the start of transmission when the functions at the sending and receiving sides are confirmed, the transmission
mode is established, and transmission and reception are synchronized.
Image transmission time:
This is the time required for the transmission of document contents (image data). In general, this time is recorded in the catalog,
etc.
Hold time:
This is the time required after the document contents have been sent to confirm that the document was actually sent, and to
check for telephone reservations and/or the existence of continuous transmission.
5.
Facsimile Standards
Item
Telephone Network Facsimile
G3 Machine
Connection Control Mode
Telephone Network Signal Mode
Terminal Control Mode
T. 30 Binary
Facsimile Signal Format
Digital
Modulation Mode
PSK (V. 27 ter) or QAM (V. 29)
Transmission Speed
300 bps (Control Signal)
2400, 4800, 7200, 9600 bps (FAX Signal)
Redundancy Compression
Process
(Coding Mode)
1 dimension: MH Mode
2 dimension: MR Mode (K=2.4)
Resolution
Main Scan: 8 pel/mm
Sub Scan: 3.85, 7.7l/mm
Line Synchronization Signal
EOL Signal
1 Line Transmission Time
[ms/line]
Depends on the degree of data reduction.
Minimum Value: 10, 20
Can be recognized in 40ms.
Summary of Contents for KX-FT981LA-B
Page 11: ...11 KX FT981LA B KX FT987LA B 6 Technical Descriptions 6 1 Connection Diagram ...
Page 13: ...13 KX FT981LA B KX FT987LA B 6 2 1 General Block Diagram ...
Page 21: ...21 KX FT981LA B KX FT987LA B 6 4 2 Block Diagram ...
Page 23: ...23 KX FT981LA B KX FT987LA B ...
Page 63: ...63 KX FT981LA B KX FT987LA B 11 2 2 User Mode KX FT987 ...
Page 71: ...71 KX FT981LA B KX FT987LA B Countermeasure ...
Page 72: ...72 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 73: ...73 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 74: ...74 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 75: ...75 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 76: ...76 KX FT981LA B KX FT987LA B ...
Page 77: ...77 KX FT981LA B KX FT987LA B ...
Page 78: ...78 KX FT981LA B KX FT987LA B REFERENCE Test Mode P 54 ...
Page 82: ...82 KX FT981LA B KX FT987LA B ...
Page 108: ...108 KX FT981LA B KX FT987LA B NG Wave pattern Note Refer to NG Example P 113 ...
Page 110: ...110 KX FT981LA B KX FT987LA B I O and Pin No Diagram ...
Page 113: ...113 KX FT981LA B KX FT987LA B 12 5 6 2 NG Example ...
Page 115: ...115 KX FT981LA B KX FT987LA B ...
Page 120: ...120 KX FT981LA B KX FT987LA B 12 5 9 2 Troubleshooting Flow Chart ...
Page 126: ...126 KX FT981LA B KX FT987LA B 12 5 13 Thermal Head Section Refer to Thermal Head P 22 ...
Page 127: ...127 KX FT981LA B KX FT987LA B 13 Service Fixture Tools ...
Page 130: ...130 KX FT981LA B KX FT987LA B 14 1 2 How to Remove the Cutter Unit KX FT987 only ...
Page 131: ...131 KX FT981LA B KX FT987LA B 14 1 3 How to Remove the Lock Lever and Thermal Head ...
Page 133: ...133 KX FT981LA B KX FT987LA B 14 2 2 How to Remove the P C Boards and Power Cord ...
Page 136: ...136 KX FT981LA B KX FT987LA B 14 3 2 How to Remove the Operation Board LCD and Platen Roller ...
Page 137: ...137 KX FT981LA B KX FT987LA B 14 3 3 How to Remove the Separation Rubber Flap ...
Page 138: ...138 KX FT981LA B KX FT987LA B 14 4 Installation Position of the Lead Wires ...
Page 139: ...139 KX FT981LA B KX FT987LA B ...
Page 147: ...147 KX FT981LA B KX FT987LA B 15 2 3 4 Copying REFERENCE Sensor Section P 123 ...
Page 152: ...152 KX FT981LA B KX FT987LA B 16 1 4 Power Supply Board ...
Page 154: ...154 KX FT981LA B KX FT987LA B 16 3 Test Chart 16 3 1 ITU T No 1 Test Chart ...
Page 155: ...155 KX FT981LA B KX FT987LA B 16 3 2 ITU T No 2 Test Chart ...
Page 168: ...168 KX FT981LA B KX FT987LA B MEMO ...
Page 178: ...178 KX FT981LA B KX FT987LA B 20 1 1 Operation Panel Section KX FT981 ...
Page 179: ...179 KX FT981LA B KX FT987LA B 20 1 2 Operation Panel Section KX FT987 ...
Page 180: ...180 KX FT981LA B KX FT987LA B 20 1 3 Upper Cabinet Section ...
Page 181: ...181 KX FT981LA B KX FT987LA B 20 1 4 Lower Cabinet Section ...
Page 182: ...182 KX FT981LA B KX FT987LA B 20 1 5 Gear Block Section ...
Page 183: ...183 KX FT981LA B KX FT987LA B 20 1 6 Screws ...
Page 184: ...184 KX FT981LA B KX FT987LA B 20 1 7 Accessories and Packing Materials ...
Page 192: ...192 KX FT981LA B KX FT987LA B K N KXFT981LAB KXFT987LAB ...