2.
Select the repeater ID to confirm the target repeater, and press
.
3.
The target repeater's Status LED will flash amber at 3 times.
2.7 Site Survey
This function can be used to measure the transmission quality, and identify problematic
transmission areas of the repeater installation. This function can be used when
registered or de-registered.
Note
• The repeater’s Site Survey mode works independently from the Base unit. This
means that the Base unit does not have to be placed into Site Survey mode.
• When using more than 1 repeater in Site Survey mode simultaneously, please ensure
repeaters are set to different channels.
1.
While pressing and holding down the PROGRAM button, turn on the repeater by
connecting the AC adaptor.
The STATUS indicator will flash red.
2.
Continue to hold down the PROGRAM button for 5 seconds.
The STATUS indicator will flash red quickly.
Note
If you continue to hold down the PROGRAM button for 10 seconds, the repeater
will enter De-registration mode.
3.
Release the PROGRAM button.
The STATUS indicator will flash red to indicate the current channel number, and a
carrier sense will start to check whether the current channel is available (idle) or
not.
4.
If the current channel is available, the STATUS indicator will change to flash green.
Site Survey mode on the current channel is now operational.
Note
A carrier sense is performed regularly in Site Survey mode. If the selected
channel is not available (busy), the STATUS indicator will flash red to indicate the
channel number and the repeater will stop transmitting.
5.
Activate the site survey function on the handset to measure the radio signal
strength level. The repeater Base unit ID is 1234567890.
Note
• It is recommended that the radio signal strength level is "03" or greater.
• For details about using the handset during a site survey, refer to the appropriate
documentation for the Base unit.
6.
To change the site survey channel, press the PROGRAM button.
2.7 Site Survey
16