background image

Installation Manual

 

Repeater

KX-A407

Model No.

Thank you for purchasing this Panasonic product.
Please read this manual carefully before using this product and save this manual for future
use.

Note

• In this manual, the suffix of each model number is omitted unless necessary.

 
Document Version: 2020-01

Summary of Contents for KX-A407 Series

Page 1: ...Thank you for purchasing this Panasonic product Please read this manual carefully before using this product and save this manual for future use Note In this manual the suffix of each model number is omitted unless necessary Document Version 2020 01 ...

Page 2: ...rmation are provided on the Panasonic Web site at https panasonic net cns pcc support sipphone Note The contents and design of the software are subject to change without notice About this Installation Manual This Installation Manual is designed to serve as an overall installation reference when using this repeater with Panasonic SIP Cordless Phones The SIP Cordless Phone base unit is described as ...

Page 3: ...ols 11 2 4 Included Accessories 11 2 5 Indicators 12 2 6 Repeater ID Confirmation 15 2 7 Site Survey 16 3 Linking to SIP Cordless Phones 18 3 1 Linking to SIP Cordless Phones 18 3 2 Compatible Devices 18 3 3 Indicators 18 3 4 Installation Registering the Repeater 19 3 5 Troubleshooting 23 4 Appendix 25 4 1 Appendix 25 4 2 Wall Mounting 25 4 3 Specifications 27 Table of Contents 3 ...

Page 4: ...rts the intended operating environment Do not change the DIP switch setting during power supplied If the product does not operate properly disconnect the AC adaptor cord then connect again The product may not operate in the event of a power failure Satisfactory operation interoperability and compatibility cannot be guaranteed with all equipment connected to the product nor with all services provid...

Page 5: ...sonic eu compliance documents Power consumption in networked standby and guidance are mentioned in the web site above For Users in the United Kingdom Only This unit is designed to be installed under controlled conditions of ambient temperature and a relative humidity Avoid installing the unit in damp or humid environments such as bathrooms or swimming pools For Users in the United States Only FCC ...

Page 6: ...with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this produc...

Page 7: ...ronic appliances such as TVs radios personal computers wireless devices or other phones facing away from radio frequency transmitters such as external antennas of mobile phone cell stations Avoid putting the repeater on a bay window or near a window Coverage and voice quality depends on the local environmental conditions If the reception for a repeater location is not satisfactory move the repeate...

Page 8: ...ive powder Disconnect the AC adaptor cord from the product before cleaning Clean the product with a soft dry cloth Do not use liquid aerosol cleaners abrasive powders or chemical agents to clean the product Placement Install the repeater within base unit range in an indoor environment We recommend installing the repeater in a raised position such as on a wall Avoid positioning the repeater close t...

Page 9: ... not available The repeater extends the range in all directions allowing several floors to be covered Note You must register the repeater with your base unit before it can be used 2 2 System Connection Example Example Connecting Repeaters and handsets SIP server A SIP server KX A407 Base unit Handset A Cascade configuration 2 Overview 9 ...

Page 10: ... the environment If the repeater s STATUS indicator and RSSI ID indicator turn green the radio signal strength level is strong after turning on the repeater the site is suitable for installing the repeater A B KX A407 Base unit A Repeater coverage area for synchronization between base unit destination repeater and repeater Maximum Distance 40 m to 50 m 98 ft to 131 ft B Repeater coverage area for ...

Page 11: ...AM Button Used to power off the repeater or to switch to Operation Mode ID Confirmation mode De registration Mode or Site Survey Mode DIP switch DC Jack Hook 2 4 Included Accessories AC adaptor 1 Screws 2 Model No Part No Washers 2 KX A407 PNLV236 KX A407UK PNLV236E KX A407CE PNLV236CE KX A407AL PNLV236AL Note For users in the United States only To order accessories call toll free 1 800 322 5368 2...

Page 12: ...ff Entering Site Survey mode 5 10 seconds 1 Quick Red Flashing De registration complete after 10 seconds 1 Red On Registration Mode Easy Manual Searching for devices Red Flashing Off Operation Mode Standby signal is strong Green On Green On Standby signal is weak Amber On Standby out of range Red On Red On Talking signal is strong Green Flashing Green On Talking signal is weak Amber On Busy signal...

Page 13: ...is strong 1 Green Flash Green ON Channel 1 signal is weak Amber ON Out of range Red ON Channel 2 signal is strong 2 Green Flashes Green ON Channel 2 signal is weak Amber ON Out of range Red ON Channel 3 signal is strong 3 Green Flashes Green ON Channel 3 signal is weak Amber ON Out of range Red ON Channel 4 signal is strong 4 Green Flashes Green ON Channel 4 signal is weak Amber ON Out of range Re...

Page 14: ...shes Green ON Channel 9 signal is weak Amber ON Out of range Red ON Channel 0 signal is strong 10 Green Flashes Green ON Channel 0 signal is weak Amber ON Out of range Red ON Firmware update mode In progress Amber Flashing Amber Flashing Success Green On Green On Amber On Failure Red On 3 seconds Red On 3 seconds RPN Radio Port Number duplication error RPN duplication Green Re d Flashing Green Re ...

Page 15: ...the number of times the RSSI ID indicator flashes green Note If the repeater loses synchronization with the destination repeater in ID Confirmation mode the repeater will automatically reset After synchronization is established the repeater will automatically enter ID Confirmation mode again 3 Return the repeater to Operation mode by pressing the PROGRAM button again ID Confirmation Mode Remote Us...

Page 16: ...u continue to hold down the PROGRAM button for 10 seconds the repeater will enter De registration mode 3 Release the PROGRAM button The STATUS indicator will flash red to indicate the current channel number and a carrier sense will start to check whether the current channel is available idle or not 4 If the current channel is available the STATUS indicator will change to flash green Site Survey mo...

Page 17: ...will change by one each time the PROGRAM button is pressed 7 To turn off Site Survey mode turn off the repeater by disconnecting the AC adaptor and then turn on the repeater by connecting the AC adaptor 2 7 Site Survey 17 ...

Page 18: ...en On Within base unit range The repeater is ready for use Flashing 1 handset is communicating with the base unit through the repeater Quick Flashing Narrowband mode 8 handsets are communicating with the base unit through the repeater Wideband mode 4 handsets are communicating with the base unit through the repeater Red On Out of base unit range Flashing The repeater is not registered to the base ...

Page 19: ...be set to 1 Off The repeater is not being used The power is off 3 4 Installation Registering the Repeater Once the repeater is connected to an AC outlet it automatically goes into registration mode if not already registered Important Before registering the repeater to the base unit you must turn the repeater mode on Refer to the appropriate documentation for the base unit If the repeater is alread...

Page 20: ...mber for about 2 seconds 4 Repeater Wait until the STATUS indicator and RSSI ID indicator turn green The repeater is ready for use If the indicators do not turn green re position the repeater in a place where the indicators turn green 5 Base unit To exit registration mode press the Handset locator button The button depends on the base unit Note The AC adaptor must remain connected at all times It ...

Page 21: ...ster to destination repeater just before starting the manual registration 1 Check the ID of the destination repeater Refer to 2 6 Repeater ID Confirmation 2 Turn on the repeater you want to register by connecting the AC adaptor The STATUS indicator and the RSSI ID indicator will turn amber for 2 seconds 3 When the repeater is unregistered The STATUS indicator will flash red When the repeater is re...

Page 22: ...lete 9 Base unit To exit registration mode press the Handset locator button De registration Perform de registration to delete the ID of the base unit repeater that the repeater is registered to 1 While pressing and holding down the PROGRAM button page 11 turn on the repeater by connecting the AC adaptor 2 Continue to hold down the PROGRAM button for 10 seconds When the STATUS indicator turns red d...

Page 23: ...lease the PROGRAM button The STATUS indicator and the RSSI ID indicator turn amber for about 2 seconds and the STATUS indicator flashes red again If the STATUS indicator flashes green after releasing the PROGRAM button deregistration failed Deregister the repeater again Re register Unplug the AC adaptor then perform from step 2 of Installation Registering the Repeater While talking using the hands...

Page 24: ...ops flashing and RSSI ID indicator turns red Then release the PROGRAM button The STATUS indicator and the RSSI ID indicator turn amber for about 2 seconds and the STATUS indicator flashes red again If the STATUS indicator flashes green after releasing the PROGRAM button deregistration failed Deregister the repeater again Re register Unplug the AC adaptor then perform from step 2 of Installation Re...

Page 25: ...astened to the wall 1 Place the reference for wall mounting on the wall to mark the 2 screw positions 2 Install the 2 screws and washers included into the wall Note Make sure that the screw heads are at the same distance from the wall Install the screws perpendicular to the wall 3 Hook the repeater on the screw heads 1 2 1 Washer 2 Drive the screw to this point 4 Appendix 25 ...

Page 26: ...nting 1 1 85 mm 3 17 50 in 1 Install a screw here Note Make sure to set the print size to correspond with the size of this page If the dimension of the paper output still deviates slightly from the measurement indicated here use the measurement indicated here 4 2 Wall Mounting 26 ...

Page 27: ...ber of repeaters is 2 when connecting with KX TGP700 base units Note The maximum number of simultaneous calls may decrease depending on the wireless environment or the PBX s system configuration General Specifications Dimensions Width Depth Height 223 mm W 110 mm D 44 mm H 8 78 in 4 33 in 1 73 in Weight 350 g 0 77 lb Power Supply AC Adaptor Input KX A407 AC 100 V 120 V 60 Hz KX A407CE KX A407UK KX...

Page 28: ... Number of Carriers KX A407 5 KX A407CE KX A407UK KX A407AL 10 Carrier Spacing 1728 kHz Bit Rate 1152 kbps Modulation Scheme GFSK Transmission Output KX A407 Peak 0 11 W KX A407CE KX A407UK KX A407AL Peak 0 25 W 1 The wireless interface differs according to the country area 4 3 Specifications 28 ...

Page 29: ... pcc support sipphone Panasonic Corporation of North America Two Riverfront Plaza Newark New Jersey 07102 5490 https panasonic net cns pcc support sipphone Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 http www panasonic com ca Panasonic Corporation 2020 PNQX8949ZA PP0420HY0 ...

Reviews: