3.7 Device Setup Window
WUME-SCLGCT-3
3-12
3.7 Device Setup Window
This window is used to set up parameters for the IO-Link device selected in the tree on the left
side of the window.
If you select an IO-Link device in the tree, a device setup subwindow will be displayed in the
Set
tab.
1
3 4 5
2
Name
Description
1
Process data display area
Process data items are displayed according to the information in the IODD
file of the IO-Link device selected in the tree. The values obtained from the
selected device are displayed as the values of the process data items.
2
Parameter display area
Parameters are displayed according to the information in the IODD file of
the IO-Link device selected in the tree.
buttons are arranged for each item, so that individual items can be
loaded.
If the user changes the value of an item, a red asterisk (*) will be displayed
at the beginning of the item.
3
Write
Clicking this button writes the parameter value(s) changed in the parameter
display area to the IO-Link device.
4
Read
Clicking this button reads all the parameter values in the parameter display
area from the IO-Link device.
5
Write Auto
If this check box is selected, when the value of any parameter displayed
in the parameter display area is changed, the value will be immediately re-
flected in the IO-Link device.
If this check box is not selected, when the value of any parameter dis-
played in the parameter display area is changed, the value will not be re-
flected in the IO-Link device until the Write button is clicked.
Summary of Contents for IO-Link SC-LG-CEF
Page 2: ...WUME SCLGCT 3 2 MEMO ...
Page 6: ...WUME SCLGCT 3 6 MEMO ...
Page 12: ...WUME SCLGCT 3 1 6 MEMO ...
Page 44: ...WUME SCLGCT 3 4 8 MEMO ...