2.17 [10] CO & Incoming Call
760
PC Programming Manual
2.17.2 [10-2] DIL Table & Port Settings
Direct In Line (DIL) or Direct Dialling In (DDI)/Direct Inward Dialling (DID) can be selected for each
trunk as the method of distributing incoming trunk calls to certain destinations. For each trunk to
which DIL distribution is set, different destinations can be programmed depending on the time mode
(day/lunch/break/night). If desired, Calling Line Identification (CLI) distribution can be used in
conjunction with DIL distribution.
For KX-TDA600, all supported cards are displayed in the
Select Shelf & Slot
list with their shelf and
slot numbers. Select the card to programme, or select "All" to display all matching cards.
DIL
For each trunk to which DIL distribution is set, different DIL destinations can be programmed
depending on the time mode (day/lunch/break/night). Generally, DIL distribution is used for trunk calls
from analogue trunks. Tenant number and VM trunk group number can also be programmed for each
trunk.
To assign DIL destination numbers, enter directly or click
Destination Setting
(see
).
Shelf (KX-TDA600 only)
Indicates the shelf position (reference only).
Value Range
Shelf number
Maintenance Console Location
2.17.2 [10-2] DIL Table & Port Settings
Programming Manual References
None
Feature Guide References
None
Slot
Indicates the slot position of each trunk card (reference only).
Value Range
Slot number
Maintenance Console Location
2.17.2 [10-2] DIL Table & Port Settings
Programming Manual References
None
Feature Guide References
None
Summary of Contents for HYBRID IP-PBX KX-TDA100
Page 10: ...10 PC Programming Manual...
Page 14: ...1 1 Introduction 14 PC Programming Manual Table 2 For CE model...
Page 15: ...1 1 Introduction PC Programming Manual 15 Table 3 For RU model...
Page 16: ...1 1 Introduction 16 PC Programming Manual Table 4 For GR model...
Page 22: ...1 2 PC Programming 22 PC Programming Manual...
Page 88: ...2 6 Utility 88 PC Programming Manual 2 Click Save Click Cancel to return to the main screen...
Page 349: ...2 9 2 System PC Programming Manual 349 Feature Guide References 1 12 1 Call Transfer...
Page 373: ...2 9 2 System PC Programming Manual 373 2 2 4 Time Service...
Page 409: ...2 9 2 System PC Programming Manual 409 1 8 4 4 Whisper OHCA...
Page 457: ...2 9 2 System PC Programming Manual 457 Feature Guide References None...
Page 486: ...2 10 3 Group 486 PC Programming Manual 2 2 2 Group...
Page 504: ...2 10 3 Group 504 PC Programming Manual Feature Guide References 1 3 1 2 Call Forwarding FWD...
Page 699: ...2 12 5 Optional Device PC Programming Manual 699 1 17 7 Automatic Fax Transfer...
Page 804: ...2 18 11 Maintenance 804 PC Programming Manual...
Page 805: ...PC Programming Manual 805 Section 3 Appendix...