background image

8

Technical data common to all models

6.  Technical data common to all models

6.1 

Hardware specifications

Touch screen technology

Resistive

Real-time clock back-up 

Supercapacitor

Fuse

Automatic

Serial port 

RS232, RS485, RS422 software configurable

Recipe memory

Flash 

Real-time clock

Clock/calendar with supercapacitor back-up

Accuracy real-time clock 

(at 25°C)

<100ppm

6.2  Environmental conditions

Operating temperature  

(surrounding air temperature)

0 to +50°C

EN 60068-2-14

Storage temperature 

-20 to +70°C

EN 60068-2-14

Operating and storage humidity 

5–85% RH not-condensing

EN 60068-2-30

Vibrations 

5–9Hz, 7mm 

p-p

9–150Hz, 1g

EN 60068-2-6

Shock

±50g, 11ms, 3 pulses per axis

EN 60068-2-27 

Degree of protection

IP66 front panel (see note)

EN 60529

Pollution degree environment

2

The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the stan

-

dards shown in the “Environmental conditions”. Even though the level of resistance unit is equivalent to these 

standards, oils that should have no effect on the HMe can possibly harm the unit. This can occur in areas 

where either vaporized oils are present, or where low viscosity cutting oil are allowed to adhere to the unit for 

long periods of time. If the front face protection sheet on the HMe becomes peeled off, these conditions can 

lead to the ingress of oil into the unit and separate protection measures are suggested.

 

If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the 

panel, the original degree of the protection cannot be guaranteed.

Summary of Contents for HMe Series

Page 1: ...TOUCH TERMINALS HMe Series Instruction Manual ACGM0195V3EN Version 1 01 ...

Page 2: ...12 8 3 HMe10 13 9 Installation 14 9 1 Installation environment 14 9 2 Installation procedure 15 10 Connections 16 10 1 HMe04 16 10 2 HMe07 17 10 3 HMe10 18 10 4 Serial port 19 10 5 Ethernet port 19 10 6 Power supply grounding and shielding 20 11 Cleaning faceplates 21 12 Getting started 21 13 System settings tool 22 13 1 Introduction 22 13 2 Activation of system settings in user mode 22 13 3 Activ...

Page 3: ... use and maintenance of programmable displays of the HMe series The following models are available HMe04 Programmable display with TFT color 4 3 widescreen display touch screen HMe07 Programmable display with TFT color 7 widescreen display touch screen HMe10 Programmable display with TFT color 10 1 widescreen display touch screen ...

Page 4: ...ANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in serious or moderate injury Notice Indicates a property damage message ...

Page 5: ...pplications with TrueType fonts Easily create install and maintain applications in multiple languages to meet global requirements Data display in numerical text bargraph analog gauges and graphic image formats Rich set of state of the art HMI features data acquisition and logging trend presentation alarm han dling scheduler and timed actions daily and weekly schedulers exception dates recipes secu...

Page 6: ...n compliance with EN 61000 6 4 EN 55011 Class A EN 61000 6 2 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 The installation of these products into the residential commercial and light industrial environments is allowed only in the case that special in measures are taken in order to ensure conformity to EN 61000 6 3 In compliance with the above regulations the products are CE mar...

Page 7: ...e attached to the rear cover You will have to know the product type you are using for correct usage of the information contained in the guide The following information is provided by the plate Product model name Product part number Year week of production Version ID of the product Serial number ...

Page 8: ...f protection IP66 front panel see note EN 60529 Pollution degree environment 2 The front face of the unit installed in a solid panel has been tested using conditions equivalent to the stan dards shown in the Environmental conditions Even though the level of resistance unit is equivalent to these standards oils that should have no effect on the HMe can possibly harm the unit This can occur in areas...

Page 9: ...e 20000 hours or more Time of continuous operation until the brightness of the backlight reaches 50 of the rated value when the surrounding air temperature is 25 C see note Front foil without direct exposure to sunlight or UV rays 10 years if the surrounding air temperature is 25 C UV resistance Indoor applications After 300 hours cycled humidity in QUV accelerated weathering some yellowing and br...

Page 10: ...3 widescreen 7 widescreen 10 1 widescreen Dimming yes User memory flash 60MB RAM 256MB DDR 512MB DDR Serial port RS232 RS485 RS422 DB9 female software configurable RS232 RS485 RS422 software configurable Ethernet port 10 100Mbit USB port Host interface V2 0 max 500mA Real time clock yes Voltage 24V DC 18 32V DC Current rating at 24V DC 0 25A 0 30A 0 38A Weight 0 4kg 0 6kg 1kg ...

Page 11: ...11 Product dimensions 8 Product dimensions 8 1 HMe04 Model A B L H D T HMe04 136mm 96mm 147mm 107mm 29mm 5mm ...

Page 12: ...12 Product dimensions 8 2 HMe07 Model A B L H D T HMe07 176mm 136mm 187mm 147mm 29mm 5mm ...

Page 13: ...13 Product dimensions 8 3 HMe10 Model A B L H D T HMe10 271mm 186mm 282mm 197mm 29mm 6mm ...

Page 14: ...ous exposure to direct sunlight This might accelerate the aging process of the front panel film The product is not intended for installation in contact with corrosive chemical compounds Check the resistance of the front panel film to a specific compound before installation Do not use tools of any kind screwdrivers etc to operate the touch screen of the product The IP66 is guaranteed only if The ma...

Page 15: ...installation please refer to the Installation Guide provided with the product Place the fixing brackets as shown in the following figure Notice Make sure to screw each fixing screw until the bezel corner gets in contact with the panel Tightening torque 75 Ncm ...

Page 16: ...16 Connections 10 Connections 10 1 HMe04 4 1 3 2 1 Serial port 2 Ethernet port 3 USB port 4 Power supply ...

Page 17: ...17 Connections 10 2 HMe07 4 1 3 2 1 Serial port 2 Ethernet port 3 USB port 4 Power supply ...

Page 18: ...18 Connections 10 3 HMe10 4 1 3 2 1 Serial port 2 Ethernet port 3 USB port 4 Power supply ...

Page 19: ...ce in the pro gramming software RS232 RS422 RS485 Pin Description Serial port Pin Description 1 GND 1 GND 2 2 3 TX 3 CHA 4 RX 4 CHB 5 5 6 5V output 6 5V output 7 CTS 7 CHB 8 RTS 8 CHA 9 9 For RS485 pins 4 3 and 8 7 must be connected externally 10 5 Ethernet port The Ethernet port has two LED status indicators They work as shown in the following table 1 2 1 Green LED 2 Yellow LED Description ON OFF...

Page 20: ...em Use terminal 3 on the power supply terminal block earth connection The power supply circuit may be floating or grounded In the latter case the power source common is connected as indicated with a dashed line in the following figure When using the floating power scheme note that internally the power common is connected to the ground with a 1MΩ resistor in parallel with a 4 7nF capacitor The powe...

Page 21: ...m v2 6 a Windows application There are two options to transfer a HMWIN application project to a panel Ethernet Connect the panel via the Ethernet interface to a personal computer running the HMWIN Studio software Select Run Download to target in HMWIN Studio Make sure that the firewall policy is configured in a way that allows HMWIN Studio to access the network USB Create an update package using t...

Page 22: ...f the panel menu and content of the selected menu item may not be displayed next to each other on the screen The system settings interface has two operating modes User mode HMWIN runtime is running or the status of the HMI panel is set to factory default System mode HMWIN runtime is not running or there is a software failure The system mode includes all options available in user mode In addition t...

Page 23: ...etting menu only System Shows information about platform status and timers e g system on time backlight on time Logs Enable persistent log for BSP and allows to export it Date Time Change the date and time of the panel including time zone and NTP server Network Configure the IP address of the Ethernet interface and the other network settings e g DNS gateway DHCP hostname Services Enable disable se...

Page 24: ...ust be high Start tapping the touch screen as soon as power has been supplied to the panel The message TAP TAP DETECTED appears when the operating sequence has been recognized Release the touch screen and wait a few seconds until the message ENTERING SYSTEM SET TINGS appears Touch and hold the touch screen for a few seconds to select TOUCHSCREEN CALIBRATION 15 Unpacking and packing instructions To...

Page 25: ...ACGM0195V3EN February 2019 Removed the pictures of the rating plates Added Important symbols page Distributed by Panasonic Electric Works Europe AG www panasonic electric works com Subject to change without notice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this documentation i...

Page 26: ...ussolengo VR Tel 39 0456752711 Fax 39 0456700444 www panasonic electric works it Nordic Countries Panasonic Electric Works Europe AG Panasonic Eco Solutions Nordic AB Filial Nordic Knarrarnäsgatan 15 164 40 Kista Sweden Tel 46 859476680 Fax 46 859476690 www panasonic electric works se Jungmansgatan 12 21119 Malmö Tel 46 40 697 7000 Fax 46 40 697 7099 www panasonic fire security com Poland Panasoni...