General Installation Manual 

© Feb 2012, SANYO Electric Co., Ltd.  All Rights Reserved 

 

 

10

Model

HIT Power 225A

HIT Power 220A

HIT Power 215A

HIT Power 210A

(VBHN225AA01)

(VBHN220AA01)

(VBHN215AA01)

(VBHN210AA01)

Cell Number in Series

72

72

72

72

Rated Power, Watts (Pmax)

225

220

215

210

Maximum Power Voltage (Vpm)

43.4

42.7

42.0

41.3

Maximum Power Current (Ipm)

5.21

5.17

5.13

5.09

Open Circuit Voltage (Voc)

53.0

52.3

51.6

50.9

Short Circuit Current (Isc)

5.66

5.65

5.61

5.57

Cell Type

HIT

HIT

HIT

HIT

Maximum System Voltage (Voc)

600

600

600

600

Factory Installed Bypass Diodes  

3

3

3

3

Maximum  series  fuse  (A)

15

15

15

15

Mechanical Specifications

Length, mm (inches)
Width, mm (inches)
Frame Depth, mm (inches)
Weight, kg (pounds)

Electrical Specifications

1580 (62.2)

798 (31.4)

46 (1.8)

16 (35.3)

SPECIFICATIONS  

 

 

 

 

P V U ‑ B 5 0 . 2

6 0 0 V

P V U ‑ B 5 0 . 2
I P 6 5

Figure 2   Dimensions

 

Dimensions

All HIT Power A Models (

VBHNxxxAA01

Label

Note : A module should be installed on a mounting structure rail in accordance with the following

 

Use four (4) symmetrical mounting within setting range A. 

: range A 

Front 

Side 

Backside

Section B-B’

Connector (MC 

TM

 Plug) 

negative (-)

103cm 
(40.6 in)

118cm 
(46.5 in)

Dimensions in mm 

Mount Locations 

Ground (4 places) 

Junction Box

positive (+)

Section A-A’

Summary of Contents for HIT Power 225A

Page 1: ...age and injury Work only in dry conditions with dry modules and dry tools Do not stand or step on modules Do not puncture cut scratch or damage the backsheet of a module Backsheet damage will void a module s Limited Warranty and may cause fire Never use modules with a damaged back sheet Do not allow children and unauthorized persons near the installation or storage site of modules Completely groun...

Page 2: ... Figure 1 A module should be attached on a mount or support structure rail by corrosive resistant metal clamps The clamps should be made of aluminum alloy or other material that will reasonably protect against the a risk of electrolytic corrosion Recommendation of bolt torque range 16N m to 20N m The module was tested using Unirac clamps with the specifications below if a different clamp is used i...

Page 3: ...nect electrical load to avoid the hazard of electrical shock To avoid the hazard of electric shock and sparks please connect each cable after confirming the polarity of them is correct Cable conduits should be used in locations where the wiring is inaccessible to children or small animals Module Wiring The number of modules that can be wired in series is recommended to be ten 10 or fewer If connec...

Page 4: ...terminal cup washers The cup washers should be stainless steel or a cup washer made of brass may be used only if a large flat washer made of stainless steel is inserted between the module frame and the cup washer Choose the adequate size for the large flat washer between the module frame and the cup washer so that the cup washer doesn t contact the module frame and is fixed stably to the module fr...

Page 5: ...l enclosure is equipped for electrical connections Modules are equipped with MC TM plugs as a terminal enclosure Use these MC TM plugs for electrical connections Junction Box and Terminals Modules are equipped with one junction box containing terminals for both positive and negative polarity and bypass diodes Each terminal is dedicated to one polarity with the polarity symbols engraved onto the bo...

Page 6: ... to inspect the electrical and mechanical connections annually If you need electrical or mechanical inspection or maintenance it is recommended to have a licensed authorized professional carry out the inspection or maintenance to avoid the hazards of electric shock or injury The return of any modules will not be accepted by SANYO unless prior written authorization has been given by SANYO As part o...

Page 7: ...between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer diameter must be greater than the cup washer diameter Cup washer Terminal cup Stainless steel or brass Star washer Stainless steel Flat washer Stainless steel Flat was...

Page 8: ...me Longer side Grounding hole 0 205 diameter 5 2mm Flat washer Stainless steel Thickness not less than 0 037 0 94 mm Diameter not less than 0 75 19 05 mm Grounding Lug Bolt Stainless steel 8 10 M5 Nut Stainless steel Copper wire Set screw Stainless screw Star washer Stainless steel Length not less than 0 63 16 mm not more than 0 78 20 mm Self tapping screw Stainless steel Copper wire Frame Longer ...

Page 9: ...ith bolt and nut Note Use the larger ground holes illustrated in Figure 3 1 Grounding Clip Assemblies Tyco Electronics 1954381 2 Glass Backsheet Frame Longer side Grounding hole 0 205 diameter 5 2mm Grounding Clip 8 32 Screw Stainless steel Nut Stainless steel Copper wire Length not less than 0 63 16 mm not more than 0 78 20 mm Copper wire Frame Longer side Glass Backsheet Grounding hole 0 165 dia...

Page 10: ...oc 600 600 600 600 Factory Installed Bypass Diodes 3 3 3 3 Maximum series fuse A 15 15 15 15 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds Electrical Specifications 1580 62 2 798 31 4 46 1 8 16 35 3 SPECIFICATIONS PVU B5 0 2 600 V PVU B5 0 2 IP6 5 Figure 2 Dimensions Dimensions All HIT Power A Models VBHNxxxAA01 Label Note A module should be inst...

Reviews: