8-8
8.4 KV-1000 Series
PLC model selection
Select “Keyence KV-1000 Series”.
Usable devices
Bit/Word Device
No.
Memo
Bit Device
Relay
00000-59915
Control Relay
CR0000-CR3915
Internal Hold Relay
MR00000-MR99915
Latch Relay
LR00000-LR99915
Timer
T0000-T3999
Counter
C0000-C3999
High-speed Counter Comparator
CTC0-CTC3
It is not possible to output
it.
Word Device
Data Memory
DM00000-DM65534
Control Memory
CM00000-CM11998
Temporary Data Memory
TM000-TM511
Enhancing Data Memory
EM00000-FM65534
Enhancing Data Memory
FM00000-FM32766
Index Register
Z01-Z12
Double Word
Device
Digital Trimmer
AT0-AT7
Timer(set Value)
T/TC0000-T/TC3999
Counter(set Value)
C/CC0000-C/CC3999
High-speed Counter
Comparator(set Value)
CTH0-CTH1
Timer(current)
T/TS0000-T/TS3999
Counter(current)
C/CS0000-C/CS3999
High-speed Counter
Comparator(current)
CTC0-CTC3
Communication Parameters Settings
The example of communication settings of GT and PLC is shown below.
Setting Values for GT (Set in the configuration setting of GTWIN.)
Item
Setting
Baud Rate
9600, 19200, 38400, 57600, 115200 bps
Data Bits
8
Stop Bits
1
Parity
Even
Summary of Contents for GT series
Page 6: ...iv...
Page 13: ...Chapter 1 Connection With Mitsubishi PLCs...
Page 38: ...1 26...
Page 39: ...Chapter 2 Connection With Omron PLCs...
Page 62: ...2 24...
Page 63: ...Chapter 3 Connection With Toshiba Machine PLCs...
Page 67: ...Chapter 4 Connection With Rockwell Automation Allen Bradley PLCs...
Page 73: ...Chapter 5 Connection With Siemens PLCs...
Page 77: ...Chapter 6 Connection With LS Industrial Systems PLCs...
Page 80: ...6 4...
Page 81: ...Chapter 7 Connection With Yokogawa PLCs...
Page 86: ...7 6...
Page 87: ...Chapter 8 Connection With Keyence PLCs...
Page 109: ...Chapter 9 Connection With Hitachi PLCs...