8-19
Communication Parameters Settings
The example of communication settings of GT and PLC is shown below.
Setting Values for GT (Set in the configuration setting of GTWIN.)
Item
Setting
Baud Rate
9600/19200/38400/57600/115200 bps
Data Bits
8
Stop Bits
1
Parity
Even
PLC Setting
Item
Setting
Operation
KV mode(high link)
Baud rate
9600/19200/38400/57600/115200 bps
RS/CS flow control
Not used
8.8.1 Connection Method
Wiring diagram
GT series
GT series RS232C
type*2 *3
GT707
*1: The numbers of module connector on the PLC show the pin numbers on the unit.
*2: Although nos.6 and 7 of the models except GT01 are RS/CS, they can be used in the above
connection.
*3: This is for RS232C type of GT01/GT02/GT02L/GT03-E/GT05/GT11/GT12/GT21/GT32/
GT32-E/GT703/GT704.