background image

7

FV-CSVK1 Condensation Sensor module

 turns the base fan on or 

boosts to higher speed when humidity is detected when used in 
combination with the FV-VS15VK1. The Condensation Sensor works 
based on calculations from the Psychrometric Chart, or combination 
of Relative Humidity (RH) and Temperature. This allows the fan to 
anticipate the formation of condensation and automatically turn on 
when needed to expel humid air. The Condensation Sensor is pre-set 
to run for 20 minutes; it will then check the RH and Temperature to 
detect if the fan needs to run for another 20 minutes cycle.

FV-MSVK1 Motion Sensor module 

turns the base fan on or boosts 

to higher speed when motion is detected when using in combination 
with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 
minutes; it will then re-check for movement; if detected the fan will 
run for another 20 minutes cycle. The Motion Sensor detects within 
the range shown below.

TM

FV-NLVK1 Nite-Glo  LED Night Light module 

automatically turns on 

when ambient light levels are met. Turning the dial on the Modular 
Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room 
with little ambient light from nearby rooms. Turning the dial to 
‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is 
necessary to connect wall switch when only plug in FV-NLVK1, fan can 
operate on high speed with wall switch control, fan can also operate 
on low speed when used in combination with the FV-VS15VK1.)

INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED 

The distance that motion 
can be detected is limited
to 10 feet (3m). The field 
of view of the sensor is 90

°

.

(Room temperature is 25 C).

PLUG ‘N PLAY Modular Component Accessories

Sold Separately, Not Included With Base Model Fan

PLUG ‘N PLAY Modular Component Accessories

Sold Separately, Not Included With Base Model Fan

FV-CSVK1 + FV-MSVK1

FV-CSVK1 + FV-VS15VK1

Turns the fan on for 20 minutes when either 
motion or excess humidity is detected.

Cycles the fan to  high speed from low speed 
for the amount of time selected on the Control 
Dial based upon detection of excess humidity.

MOTION (PLUG ‘N PLAY FUNCTION DEVICES) 

PLUG ‘N PLAY Modular 
Components used in 
Combinations

FV-MSVK1 + FV-VS15VK1

Cycles the fan to  high speed from low speed 
for the amount of time selected on the Control 
Dial based upon motion within the room.

Fan 
operation

Time delay 
operation

OUTSIDE

Human 
active

Motion

Module FV-MSVK1, 

FV-CSVK1 (Not 

included)

INSIDE

FV-CSVK1 only

Fan 
ON/OFF

20 minutes 
time delay

FV-MSVK1 only

Fan 
active

At low 
speed

When motion or 
excess humidity is 
detected, fan runs 
at high speed.

Remains running 
at high speed until 
the delay time has 
passed.

FV-CSVK1 + FV-VS15VK1

Fan 
Hi/Low speed

Depend on 
FV-VS15VK1 Time 
delay setting

FV-MSVK1 + FV-VS15VK1

Summary of Contents for FV-05-11VKL1

Page 1: ...11 15VKL1 INSTALLATION INSTRUCTIONS Ventilating Fan Model No Contents FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models 2 3 3 4 4 4 5 5 5 6 6 7 7 8 8 10 10 11 11 BACK COVER BACK COVER BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product F...

Page 2: ...ribe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed To reduce the risk of fire electric shock or injury to persons observe the following CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury The following symbols are used to classify and describe the ...

Page 3: ...ith a method which is not approved in the instructions WARNING This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmonic distortion which can cause motor humming noise When this product is no longer being operated please remove the product to prevent the possibility of falling GENERAL SAFETY INFORMATION CONTINUED Pr...

Page 4: ...egral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A damper for preventing air counter flow is provided The blower uses a high capacity sirocco fan developed to reduce the noise level FCC Note This equipment has been tested and found to comply with the...

Page 5: ...Light Neutral Power supply AC120V 60Hz AC120V 60Hz Power supply Neutral Black Red Red Green Earth ground Green White White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module switch When plug in other Plug N Play modules On Off Non powered control wires 15 9 2 4 8 1 3 5 6 7 10 11 13 12 14 LED lamp Motion sensor location FV MSVK1 not included Multi Speed module FV 05 11VKSL...

Page 6: ...s the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70...

Page 7: ...necessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICATION PLUG N PLAY FUNCTION DEVICES CONTINUED The distance that motion can be detected is limited to 10 feet 3m The field of view of the sensor is 90 Room temperature is 25 C PLUG N PLAY Modular Compone...

Page 8: ...tor from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from 16 to 24 on center can be adjusted flexibly 2 Bend down 4 tabs for positioning install the TM Flex Z Fast bracket to joists by using 2 tapping screws ST4 2X20 Please prepare the screws and TM TM put ...

Page 9: ... black Light Netural to white Netural to white Junction box Two red wires Connect to a general manual wall switch Earth ground to green INSTALLATION NEW CONSTRUCTION CONTINUED CAUTION CAUTION Machine screw M4X6 2 Self drilling screws Joist Plug connector Receptacle 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 Fig 7 10 1 2 270 1 0 1 2 2 7 0 Ceiling U...

Page 10: ... fan body to adaptor by using machine screw M4X6 Fig 16 Secure machine screw M4X6 to the suitable TM hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth Ceiling Flange Joist Machine screw M4X6 2 Self drilling screws Fix the TM flange and Flex Z Fast bracket through the ceiling 15 Adjust Pick A Flow switch if used adjust the FV VS15VK1 Multi Speed mod...

Page 11: ...ot immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C WARNING CAUTION 4 Install the LED lamps CX GU24 H B 7W as shown in step 1 and step 2 of Fig 9 Page 9 WARNING Remove dust and dirt from light cover and lens before replace the lamps The LED lamps should be replaced as the specified type The supplied LED lamps are not intended for other use CAUTION 3 Replace the...

Page 12: ...irection Exhaust Exhaust Exhaust 4 or 6 Exhaust Voltage V Voltage V Frequency Hz Frequency Hz Noise sones Noise sones Speed rpm Speed rpm Power W Power W Fan Fan Lighting unit Lighting unit Weight lb Weight lb Duct diameter inches Duct diameter inches Air volume at 0 1 WG CFM Air volume at 0 1 WG CFM Panasonic corporation 2014 FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 FV 05 11VKSL1 FV 05 11VKL1 Plug...

Reviews: