background image

Panasonic Corporation of North America

Panasonic Canada lnc.

www.panasonic.com

5770 Ambler Drive, Mississauga, Ontario L4W 2T3
www.panasonic.ca

Printed in China

Properly  insulate  the  area  around  the  fan  to
minimize  building  heat  loss  and  gain.  (Fig.23)
Loose  fill  or  batt  insulation  can  be  placed
directly  over  the  fan  housing  in  the  attic.
Our  fans  and  fan/light  combination  units  do
not  create  excessive  heat  that  is  a  common
problem  with  recessed  light  fixtures  or  some
competitor’s  fan/light  combination.  Our
efficient,  cool-running  motors  and  our  LED
lighting  unit  do  not  create  enough  ambient
heat  to  be  subjected  to  these  limitations.

4 inches or 6 inches roof jack, wall cap,
or soffit vent with backdraft damper

Mechanically connect duct to termination
and seal with mastic or approved foil
faced tape

2-3 ft straight run before elbow

In attic installation,
caulk box to drywall

PRACTICAL GUIDE TO INSTALLATION

SPECIFICATIONS

PRODUCT

 

SERVICE

Specifications for Base Model fans

HVI Certified performance based on HVI Procedures 915, 916, and 920.

Reference performance based on HVI Procedures 915, 916, and 920. [( ) Standby wattage.]

*

Specifications for Multi Speed fans

Model No.

Model No.

Air

direction

Air

direction

Exhaust

Exhaust

Exhaust

4 or 6

Exhaust

Voltage

(V)

Voltage

(V)

Frequency

(Hz)

Frequency

(Hz)

Noise

(sones)

Noise

(sones)

Speed

(rpm)

Speed

(rpm)

Power

 

(W)

Power

 

(W)

Fan

Fan

Lighting

unit

Lighting

unit

Weight

lb

.

Weight

lb

.

Duct

diameter

(inches)

Duct

diameter

(inches)

Air volume

at 0.1"WG

(CFM)

Air volume

at 0.1"WG

(CFM)

Panasonic  corporation  2014

FV-05-11VKSL1
FV-05-11VKL1

FV-11-15VKL1

FV-05-11VKSL1,

FV-05-11VKL1
(Plug-in 
FV-VS15VK1)

X0114-2024   11KSL1420B

14

14

110

<0.3
<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

0.4

<0.3

<0.3

0.6

8.5

8.7

3.6

4.7

12.0

7.0

6.0

3.9

16.5

6.0

11.0

3.6
2.8
2.5

650

915

680

865

730

825

750

795

825

770

730

965

750

725

110

80

60

40

0

130
150

50
80

90

70

50

30

100

11.5(5.2)

11.5(5.2)

FV-11-15VKL1
(Plug-in 
FV-VS15VK1)

14

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

9.5

5.7

8.5

5.0

6.9

4.3
4.0
3.2

665
650
645
640
635

625

630

620

100

80

60

0

110

90

70

50

120

11.7(5.3)

11.7(5.3)

14

3

Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. 
Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit 
require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).

Two Riverfront Plaza, Newark, NJ 07102

Short piece of flexible duct helps
alignment and absorbs sound.
Clamps plus mastic or approved
foil faced tape at all flex joints

Foil tape tightly covers all metal
duct joints (glue PVC joints)

Insulation

Summary of Contents for FV-05-11VKL1

Page 1: ...11 15VKL1 INSTALLATION INSTRUCTIONS Ventilating Fan Model No Contents FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 Representative models 2 3 3 4 4 4 5 5 5 6 6 7 7 8 8 10 10 11 11 BACK COVER BACK COVER BACK COVER READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product F...

Page 2: ...ribe the level of hazard injury and property damage caused when the denotation is disregarded and improper use is performed To reduce the risk of fire electric shock or injury to persons observe the following CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury The following symbols are used to classify and describe the ...

Page 3: ...ith a method which is not approved in the instructions WARNING This product must be properly grounded Do not use this fan with any solid state speed control device Solid state controls may cause harmonic distortion which can cause motor humming noise When this product is no longer being operated please remove the product to prevent the possibility of falling GENERAL SAFETY INFORMATION CONTINUED Pr...

Page 4: ...egral transformer The motor is designed to have long operating life high dynamic response higher speed ranges with saving energy The grille covering the fan body is a spring loaded quick remove type A damper for preventing air counter flow is provided The blower uses a high capacity sirocco fan developed to reduce the noise level FCC Note This equipment has been tested and found to comply with the...

Page 5: ...Light Neutral Power supply AC120V 60Hz AC120V 60Hz Power supply Neutral Black Red Red Green Earth ground Green White White 114 C Fuse Thermally protected Hi Low switch When plug in Multi Speed module switch When plug in other Plug N Play modules On Off Non powered control wires 15 9 2 4 8 1 3 5 6 7 10 11 13 12 14 LED lamp Motion sensor location FV MSVK1 not included Multi Speed module FV 05 11VKSL...

Page 6: ...s the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70...

Page 7: ...necessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICATION PLUG N PLAY FUNCTION DEVICES CONTINUED The distance that motion can be detected is limited to 10 feet 3m The field of view of the sensor is 90 Room temperature is 25 C PLUG N PLAY Modular Compone...

Page 8: ...tor from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As shown below The fan position between joists from 16 to 24 on center can be adjusted flexibly 2 Bend down 4 tabs for positioning install the TM Flex Z Fast bracket to joists by using 2 tapping screws ST4 2X20 Please prepare the screws and TM TM put ...

Page 9: ... black Light Netural to white Netural to white Junction box Two red wires Connect to a general manual wall switch Earth ground to green INSTALLATION NEW CONSTRUCTION CONTINUED CAUTION CAUTION Machine screw M4X6 2 Self drilling screws Joist Plug connector Receptacle 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 Fig 7 10 1 2 270 1 0 1 2 2 7 0 Ceiling U...

Page 10: ... fan body to adaptor by using machine screw M4X6 Fig 16 Secure machine screw M4X6 to the suitable TM hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth Ceiling Flange Joist Machine screw M4X6 2 Self drilling screws Fix the TM flange and Flex Z Fast bracket through the ceiling 15 Adjust Pick A Flow switch if used adjust the FV VS15VK1 Multi Speed mod...

Page 11: ...ot immerse motor in water when cleaning Do not soak resin parts in water over 140 F 60 C WARNING CAUTION 4 Install the LED lamps CX GU24 H B 7W as shown in step 1 and step 2 of Fig 9 Page 9 WARNING Remove dust and dirt from light cover and lens before replace the lamps The LED lamps should be replaced as the specified type The supplied LED lamps are not intended for other use CAUTION 3 Replace the...

Page 12: ...irection Exhaust Exhaust Exhaust 4 or 6 Exhaust Voltage V Voltage V Frequency Hz Frequency Hz Noise sones Noise sones Speed rpm Speed rpm Power W Power W Fan Fan Lighting unit Lighting unit Weight lb Weight lb Duct diameter inches Duct diameter inches Air volume at 0 1 WG CFM Air volume at 0 1 WG CFM Panasonic corporation 2014 FV 05 11VKSL1 FV 05 11VKL1 FV 11 15VKL1 FV 05 11VKSL1 FV 05 11VKL1 Plug...

Reviews: