● The instruction can be executed when the transfer request relays of the FTPc control relay
and the FTPc logging/trace control relay are OFF (0: No request). As an execution condition
of the instruction, insert a program that checks the state of the transfer request relay. The
states of the transfer request relay and the logging transfer request relay can be read with
the ETSTAT instruction. Store the state that is read in a device such as an internal relay. An
operation error occurs if the instruction is executed when one of the transfer request relays is
ON.
● After this instruction is executed, the PLC operates as shown in the following table.
Conditions
Operation
The power supply for the PLC is switched from OFF to ON.
Setting using the
configuration
The PLC is changed to
PROG mode.
Changes to RUN mode without rewriting the
configuration.
Setting using instructions
Changes to RUN mode after rewriting the
configuration.
Setting using the
configuration
● If an incorrect IP address is specified, the system relay SR9 (carry flag CY) is set and the
instruction is terminated without being executed.
● This instruction can be executed when the Ethernet initialization active flag (X61) is OFF. As
an execution condition of the instruction, insert a program that checks the status of the flag
(X61). If this instruction is executed when the flag (X61) is ON, the system relay SR9 (carry
flag CY) is set and the instruction is terminated without being executed.
● When the instruction is completed successfully, the system relay SR9 (carry flag CY) and the
system data register SD29 (Ethernet communication error code) are cleared.
■
Precautions for programming
● Insert the UNITSEL instruction immediately before this instruction and specify the unit (built-
in ET-LAN in the CPU unit) and the connection number.
● For [S1] to [S3], specify the starting address of the device area that stores the string data
that indicates the set parameters, or a character constant. When specifying a device area for
an operand, set string data using the SSET instruction in advance. However, the ESSET
instruction cannot be used because the format is different. The number of characters should
not exceed 256.
● Both upper and lower case characters can be used. "Abcd", "ABCD" and "abcd" are all
synonymous. "Abcd", "ABCD" and "abcd" are all synonymous.
● This instruction is not available in interrupt programs.
■
Operand [S1] setting
● Specify the starting address storing the server specification parameter or a character
constant.
● A part of parameters can be omitted. The settings are not changed when parameters are
omitted partially.
● When omitting the part before a specified keyword, omit only "keyword" without omitting ",".
● When omitting the part after a specified keyword, omit both "," and "keyword".
● Specify the FTP server setting from SV0 in order. When the right order is skipped, an error
occurs. It is possible to specify when the setting has been already registered.
● Only one server can be specified at the same time.
● Specify an FTP server number, the IP address or host name of an FTP server, a port
number, an open method, and the SSL3/TLS1 authentication setting within 256 one-byte
characters in total.
17.11 FTPcSV (FTP Client Connected Server Setting)
WUME-FP7CPUPGR-12
17-53
Summary of Contents for FP7 Series
Page 2: ... MEMO 2 WUME FP7CPUPGR 12 ...
Page 18: ... MEMO xviii WUME FP7CPUPGR 12 ...
Page 52: ... MEMO 1 34 WUME FP7CPUPGR 12 ...
Page 104: ... MEMO 2 52 WUME FP7CPUPGR 12 ...
Page 123: ...3 9 ANS AND stack WUME FP7CPUPGR 12 3 19 ...
Page 125: ...3 10 ORS OR Stack WUME FP7CPUPGR 12 3 21 ...
Page 129: ...3 11 PSHS Push stack RDS Read stack POPS Pop stack WUME FP7CPUPGR 12 3 25 ...
Page 190: ...3 26 JP LBL Jump Label 3 86 WUME FP7CPUPGR 12 ...
Page 239: ...Name Description SR8 ER 3 46 ST ST ST ST ST ST Data Comparison Start WUME FP7CPUPGR 12 3 135 ...
Page 246: ... MEMO 3 142 WUME FP7CPUPGR 12 ...
Page 258: ... MEMO 4 12 WUME FP7CPUPGR 12 ...
Page 304: ... MEMO 5 46 WUME FP7CPUPGR 12 ...
Page 321: ...Name Description ER 6 7 DIVFP2 Division FP2 Compatible WUME FP7CPUPGR 12 6 17 ...
Page 348: ... MEMO 6 44 WUME FP7CPUPGR 12 ...
Page 388: ... MEMO 7 40 WUME FP7CPUPGR 12 ...
Page 438: ... MEMO 8 50 WUME FP7CPUPGR 12 ...
Page 450: ... MEMO 9 12 WUME FP7CPUPGR 12 ...
Page 520: ... MEMO 10 70 WUME FP7CPUPGR 12 ...
Page 602: ... MEMO 11 82 WUME FP7CPUPGR 12 ...
Page 622: ... MEMO 12 20 WUME FP7CPUPGR 12 ...
Page 650: ... MEMO 13 28 WUME FP7CPUPGR 12 ...
Page 1160: ... MEMO 18 66 WUME FP7CPUPGR 12 ...
Page 1188: ... MEMO 19 28 WUME FP7CPUPGR 12 ...
Page 1220: ... MEMO WUME FP7CPUPGR 12 ...
Page 1221: ... MEMO WUME FP7CPUPGR 12 ...