(Note 1)
The start area (storage area size) for [D] is set before executing this instruction.
(Note 2)
The data out of the destination range does not change.
Example 2) When inserting into the text a conversion form (%d) that represents a 16-
bit signed integer
In the place of the conversion form (%d), the ASCII code that is equivalent to the integer data
specified by [S2] is inserted. If a number of digits is not specified for the conversion form, the
number of converted data and the size of the storage area will vary according to the value [S2].
- Image of mail text
Production volume: 5
S1="Production volume: %u"
S2=DT1
D=DT50
- Setting values
DT1
U 5
DT2
DT3
DT51
No. of bytes
DT52
DT53
DT54
DT55
DT56
DT57
H 76 (v)
DT58
DT59
DT60
DT61
Data part
H 6e (n)
H 69 (i)
H 63 (c)
H64 (d)
H 72 (r)
U 20
H 6c (l)
H 6d (m)
H 3a (:)
H 35 (5)
H 20 (SPACE)
H 6f (o)
H 74 (t)
H 75 (u)
H 6f (o)
H 50 (P)
H 6f (o)
H 75 (u)
H 65 (e)
H 20 (SPACE)
DT50
Storage area size (*1)
U 22
DT62
(*2)
(Note 1)
The start area (storage area size) for [D] is set before executing this instruction.
(Note 2)
The data out of the destination range does not change.
Example 3) When inserting into the text a horizontal tab code (\t: H09)
In the place of the conversion form (\t), the ASCII code that is equivalent to the horizontal tab
code is inserted. If a conversion form is not included in [S1], the data for [S2] will have no effect
on the conversion results.
14.27 EPRINT (Text Creation: With Storage Area Size)
14-110
WUME-FP7CPUPGR-12
Summary of Contents for FP7 Series
Page 2: ... MEMO 2 WUME FP7CPUPGR 12 ...
Page 18: ... MEMO xviii WUME FP7CPUPGR 12 ...
Page 52: ... MEMO 1 34 WUME FP7CPUPGR 12 ...
Page 104: ... MEMO 2 52 WUME FP7CPUPGR 12 ...
Page 123: ...3 9 ANS AND stack WUME FP7CPUPGR 12 3 19 ...
Page 125: ...3 10 ORS OR Stack WUME FP7CPUPGR 12 3 21 ...
Page 129: ...3 11 PSHS Push stack RDS Read stack POPS Pop stack WUME FP7CPUPGR 12 3 25 ...
Page 190: ...3 26 JP LBL Jump Label 3 86 WUME FP7CPUPGR 12 ...
Page 239: ...Name Description SR8 ER 3 46 ST ST ST ST ST ST Data Comparison Start WUME FP7CPUPGR 12 3 135 ...
Page 246: ... MEMO 3 142 WUME FP7CPUPGR 12 ...
Page 258: ... MEMO 4 12 WUME FP7CPUPGR 12 ...
Page 304: ... MEMO 5 46 WUME FP7CPUPGR 12 ...
Page 321: ...Name Description ER 6 7 DIVFP2 Division FP2 Compatible WUME FP7CPUPGR 12 6 17 ...
Page 348: ... MEMO 6 44 WUME FP7CPUPGR 12 ...
Page 388: ... MEMO 7 40 WUME FP7CPUPGR 12 ...
Page 438: ... MEMO 8 50 WUME FP7CPUPGR 12 ...
Page 450: ... MEMO 9 12 WUME FP7CPUPGR 12 ...
Page 520: ... MEMO 10 70 WUME FP7CPUPGR 12 ...
Page 602: ... MEMO 11 82 WUME FP7CPUPGR 12 ...
Page 622: ... MEMO 12 20 WUME FP7CPUPGR 12 ...
Page 650: ... MEMO 13 28 WUME FP7CPUPGR 12 ...
Page 1160: ... MEMO 18 66 WUME FP7CPUPGR 12 ...
Page 1188: ... MEMO 19 28 WUME FP7CPUPGR 12 ...
Page 1220: ... MEMO WUME FP7CPUPGR 12 ...
Page 1221: ... MEMO WUME FP7CPUPGR 12 ...