EN
EN
- 1 -
EN
EN
Setting the snug point detec
tion level
EYFA31
A
B
C
D
()
()
(1)
1. Press the A button.
• The snug point detection level setting
value will be displayed.
Display
Battery indication lamp
. Press the and buttons to set the best
snug point detection level for the work
you’re performing.
. Press the OK button to accept the number
of torque stages and the snug point detec-
tion level.
• The tool’s panel will flash and then light
up continuously.
Snug point detection level guide
lines
Display
Snug point
detection level
Applications
(reference)
L1
Low
(Use for work
characterized by
low loads before
the snug point is
reached.)
• Tightening bolts in
materials that are
easily cracked or
deformed, etc.
L
High
(Use for work
characterized
by high loads
before the
snug point is
reached.)
• Tightening bolts
in materials with
misaligned holes,
etc.
• Tightening self-
tapping screws,
etc.
CAUTION:
• Set the snug point detection level from
“L1.” Setting the snug point detection level
from “L2” may result in cracking or defor
-
mation of the target material.
• If the tool stops before the snug point at
snug point detection level “L1,” set the
snug point detection level to “L2.”
• Changing the snug point detection level
from “L1” to “L2” may increase the torque.
Set the number of torque stages again
after making this change.
• The setting will not be changed until
you press the OK button.
• After changing the setting, be sure to check
the new setting value. (See page 16.)
IMPORTANT INFORMATION:
• You can set the snug point detection
level and retightening prevention time at
the same time by changing the retight-
ening prevention time (See page 1)
before pressing the OK button and then
pressing the OK button.
• Pressing the A button toggles the dis-
play between the snug point detection
level setting value and the number of
torque stages setting value.
• The tool ships with the snug point
detection level set to “L1.”
• When the number of torque stages has
been set as shown below, the snug
point detection level cannot be switched
from “L1” to “L2.”
Model
Number of torque stages
setting
EYFPA
1 to 0
Cross thread reduction func
tion
• The tool runs in reverse approximately
60° before running forward to assist in
the alignment of the threads to help reduce
cross threads.
1. Set the tool to setting configuration mode.
(See page 11.)
. Press the D button once.
• The cross thread reduction function set-
ting value will be displayed.
. Press the and buttons to change the
setting to ON or OFF.
Display
Function
R0
OFF
R1
ON
4. Press the OK button to accept the new
setting.