Accessing Wiring
Initiate a Rapid Shutdown and allow the DC voltage to drop to a safe level.
Power down inverter and disconnect all wiring sources of AC and DC
power.
WARNING:
Exposed hazardous voltage, during servicing or
for emergency procedures use a lockable manual breaker
lockout on the main serice panel disconnects to enable
Lock-Out-Tag-Out per the Standard for Electical Safety in
the Workplace, NFPA 70E, and the Standard for Workplace
Electrical Safety, CA Z462.
WARNING:
These servicing instructions are for use by
qualified personnel only. To reduce the risk of electric shock,
do not perform any servicing other than that specified in the
operating instructions unless you are qualified to do so.
18. TROUBLESHOOTING
Waking Up the Batteries (Optional)
When waking up the batteries for the first time, you may receive an Error
27 (battery voltage under 30V). To clear this error, turn of the inverter
using the main switch and then turn it back on.