http://cxema.ru
Current
mode
Battery
Voltage
HF
nIGNITION
EXTINT
KBR0
EXT_PWR
_SENSE
Power down
New mode
X
X
X
1
X
<0.5V
normal
OFF
X
X
X
X
0
X
X
emergency
OFF
X
X
X
X
1
1
<0.5V
normal
OFF
active
<4.0V
X
X
1
0
>1.2V
normal
restricted
active
<4.0V
no
X
1
1
>1.2V
normal
charge
active
<4.0V
yes
>2.5V
1
1
X
normal
OFF
active
<4.0V
yes
<0.5V
1
1
>1.2V
normal
charge
active
<4.0V
yes
>2.5V
1
0
X
normal
OFF
active
X
no
X
1
1
>1.2V
normal
charge
active
X
yes
<0.5V
1
1
>1.2V
normal
charge
active
X
yes
>2.5V
1
1
X
normal
OFF
active
X
yes
>2.5V
1
0
>1.2V
normal
OFF
active
X
X
X
1
0
<0.5V
normal
OFF
9.5
PowerManagement
The Power supply circuit needs to supply regulated power to the baseband and RF parts, control battery charging
and monitor battery usage.
G600 must achieve 2 types of battery operation - 4 cell Ni-MH and 2 cell Li-ION.
The power supply section consists of four parts;
1. Power-on circuitry,
2. Voltage regulators,
3. Battery charging circuitry,
4. Power fail detection.
In order to reduce the size and weight of the phone, two Li-ION cells have been chosen as the main power source.
To reduce the cost of the phone four Ni-MH cells can be used as the optional power source. The Li-ION standard
battery gives 400mAH (typical) capacity. The optional Ni_MH battery gives 670mAH capacity.
Battery operating voltage range:
4.5V
(minimum safe discharge)
6V
(maximum fully charged Ni-MH)
8.2V
(maximum fully charged Li-ION)
The G600 battery management operates with the following voltage levels:
Battery Voltage
Li-ION
Ni-MH
B-Icon 3 bar
7.55<
4.90<
B-Icon 2 bar
7.20<
<7.55
4.75<
<4.90
B-Icon 1 bar
6.00<
<7.20
4.50<
<4.75
LVA
<6.00
<4.50
Issue 1
Section 9
MCUK980101G8
Revision 0
9 - 4
Technical Guide
POWER SUPPLIES