PRINTER Laser Duty Adj
Printer Density Adjustment for Printer.
(-) : Darker.
(+) : Lighter.
-99 - +99
47
Transfer Current Side 2
Adjustment of Transfer Current.
-62 - +110
0.15uA
48
Transfer Current Envelope
Adjustment of Transfer Current.
-62 - +110
0.15uA
49
T Mode Image Density
Image density adjustment for Text mode.
(-) : Darker.
(+) : Lighter.
-99 - +99
50
T/P Mode Image Density
Image density adjustment for Text/ Photo
mode.
(-) : Darker.
(+) : Lighter.
-99 - +99
51
P Mode Image Density
Image density adjustment for Photo mode.
(-) : Darker.
(+) : Lighter.
-99 - +99
52
Not Used
53
CCD Read Position Adj
Adjustment of CCD read position.
-42 - +44
0.2mm
54
T Mode Contrast
Adjustment of Contrast for Text Mode.
-128 - +127
55
T/P Mode Contrast
Adjustment of Contrast for Text/Photo Mode.
-128 - +127
56
P Mode Contrast
Adjustment of Contrast for Photo Mode.
-128 - +127
57
Not Used
58
Corona Charger Current
Adjustment of Corona Charge Current.
-77 - +76
1.3uA
59
Trail Edge Trans (Trays)
Trail Edge Transfer Image High Voltage
Timing Adjustment for Trays 1-4 feeding.
-30 - +30
0.5mm
60
Trail Edge Trans (Bypass)
Trail Edge Transfer Image High Voltage
Timing Adjustment for Bypass Tray feeding.
-30 - +30
0.5mm
61
Trail Edge Trans (2Sided)
Trail Edge Transfer Image High Voltage
Timing Adjustment for the 2nd side of 2-Sided
printing.
-30 - +30
0.5mm
62
TDC Gain Voltage Adjust
Adjustment of Toner Density sensor gain
voltage.
-10 - +10
0.033V
63
Lead Edge Read Timing
(Adjustment for Double Exposure
Copy Mode, for details, and
adjustment procedure, refer to
Sect. 3.9.8.)
Adjustment of Lead Edge Read Point.
0 - +9
0.5mm
64
Side Edge Read Adjust
(Adjustment for Double Exposure
Copy Mode, for details, and
adjustment procedure, refer to
Sect. 3.9.8.)
Adjustment of Side Edge Read Point.
0 - +9
0.5mm
65
Transfer Current Side 1
(Small Width)
(Factory use only)
Adjustment of Transfer Current.
-20 - +20
0.15uA
F6 Mode
No.
Item
Remarks
Setting
Range
Summary of Contents for DP-8020E
Page 2: ...2 ...
Page 5: ...5 ...
Page 10: ...10 ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 105: ...105 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P DETAIL A 28 35 31 32 33 34 30 29 ...
Page 466: ...466 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P memo ...
Page 497: ......