234
SEP 2006
Ver. 1.0
DP-8020E/8020P/8016P
503
XMT/
RCV(V.34)
B, C, D CS of modem is not able to turn
ON during training.
FXB PCB defective.
Line disconnected.
504
RCV/V.34
(Polling)
B
Polling is rejected from the remote
station.
No polling original set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling original set.
540
XMT ECM
B
No response after transmitting 3rd
CTC, or DCN received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd
EOR, or received DCN.
Faulty line.
MJR PCB abnormal.
542
XMT ECM
D
No response to the 3rd RR
transmitted, or received DCN.
Remote unit abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without
MCF.
Remote unit abnormal.
544
XMT ECM
D
Stopped Transmission after EOR
Transmission.
Faulty line.
MJR PCB abnormal.
550
RCV ECM
C
Timer between frames in phase C
has elapsed.
Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving
EOR.
Faulty line.
555
RCV ECM
D
Transmitted PIN after receiving
EOR.
Faulty line, and Operator Call requested
by RX side.
570
RCV
B
Password, or machine code did
not match during remote
diagnostic communication.
571
XMT
B
Remote unit did not have the
remote diagnostic function.
580
XMT
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
581
XMT
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
582
XMT
B
Sub-address SEP (for Polling)
transmission to a unit that has their
DIS bit 47 (NSF bit 130) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
601
XMT
ADF Door was opened during ADF
transmission.
623
XMT
A
No original was in the ADF. (Built-
in dialer engaged)
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
630
XMT, or
RCV
(Polling)
B
Redial count over.
No dial tone detected. Sensor did not
detect dial tone. (Country dependent)
Busy tone is detected. (Country
dependent) T1 timer (35±5 sec) elapsed
without a signal from the receiver.
631
XMT
A
"STOP" key was pressed during
Auto Dialing.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Possible Cause(s)
Summary of Contents for DP-8020E
Page 2: ...2 ...
Page 5: ...5 ...
Page 10: ...10 ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 105: ...105 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P DETAIL A 28 35 31 32 33 34 30 29 ...
Page 466: ...466 SEP 2006 Ver 1 0 DP 8020E 8020P 8016P memo ...
Page 497: ......
Page 498: ...Published in Japan ...