270
UF-9000
APR 2006
Ver. 3.0
DP-180/190
3)
Preparing the Main Unit for the Programming Master Firmware Card
Important: DO NOT connect the USB Cable yet.
1. Turn the Power Switch on the left side of the machine to the OFF position. (During a Lightning
Storm, to prevent electrocution disconnect the Telephone Line Cable first before unplugging the AC
Power Cord.)
2. Insert/Remove the Flash Memory Card (4 MB or 8 MB) into/from the machine.
3. Turn the Power Switch on the Left Side of the machine to the ON position.
4. Press
“FUNCTION”
,
“ORIGINAL SIZE”
keys, and then Key
“3”
on the keypad sequentially.
5. Perform the Update Program Card Mode F9-09
(Update Program Card)
.
The unit is now ready to accept the firmware code from the USB Port.
Now connect the USB Cable between the Unit, and PC.
(Refer to the Local Firmware Update Tool OI on the CD)
Repeat the above steps if there are additional master firmware cards to be programmed.
B. Copying the Firmware from an Existing Machine using a Flash Memory Card (4 MB or 8 MB)
1. Turn the Power Switch on the left side of the machine to the OFF position. (During a Lightning
Storm, to prevent electrocution disconnect the Telephone Line Cable first before unplugging the AC
Power Cord.)
2. Install a Flash Memory Card (4 MB or 8 MB) into the machine.
3. Turn the Power Switch on the Left Side of the machine to the ON position.
4. Press
“FUNCTION”
,
“ORIGINAL SIZE”
keys, and then Key
“3”
on the keypad sequentially.
5. Perform the Copy Service Mode F9-08
(Program Backup)
.
6. The firmware is copied into the Flash Memory Card.
7. After the backup is completed, press
"STOP"
first, and then press
"FUNCTION"
+
"CLEAR"
keys
simultaneously to return to standby.
8. Turn the Power Switch on the left side of the machine to the OFF position.
9. Remove the Master Firmware Card that you just created from the machine.
10. Turn the Power Switch on the Left Side of the machine to the ON position.
11. Use this Master Firmware Card to update the firmware on other machines.
8.1.3.2.
Erasing the Master Firmware Card
1. Turn the Power Switch on the left side of the machine to the OFF position. (During a Lightning
Storm, to prevent electrocution disconnect the Telephone Line Cable first before unplugging the AC
Power Cord.)
2. Install the Master Firmware Card into the machine.
3. Turn the Power Switch on the Left Side of the machine to the ON position.
4. Press
“FUNCTION”
,
“ORIGINAL SIZE”
keys, and then Key
“3”
on the keypad sequentially.
5. Perform the Service Mode F9-09
(Update Program Card)
.
6. After the Flash Memory Card is erased, machine prompts
“READY TO PROGRAM PRESS SET
TO START”
. Press
“STOP”
.
7. Press
"STOP"
first, and then press
"FUNCTION"
+
"CLEAR"
keys simultaneously to return to
standby.
8. Turn the Power Switch on the left side of the machine to the OFF position.
9. Remove the blank Flash Memory Card from the machine.
10. Repeat from Step 2 above if you are erasing another Master Firmware Card.
Summary of Contents for DP-180
Page 50: ...50 UF 9000 APR 2006 Ver 3 0 DP 180 190 21 Remove the LCD Module 127 ...
Page 74: ...74 UF 9000 APR 2006 Ver 3 0 DP 180 190 3 3 Preventive Maintenance Points ...
Page 126: ...126 UF 9000 APR 2006 Ver 3 0 DP 180 190 Sensor and Switch Location ...
Page 341: ...341 UF 9000 APR 2006 Ver 3 0 DP 180 190 memo ...
Page 343: ...343 APR 2006 Ver 3 0 UF 9000 DP 180 190 memo ...
Page 359: ...Published in Japan ...
Page 375: ...Published in Japan ...