172
UF-9000
APR 2006
Ver. 3.0
DP-180/190
Note 1:
Continuous Polling (Station Mode)
This feature allows you to store or add documents into a polled file in memory.
To enable the Continuous Polling feature set Function Parameter No. 003 to "2:Station".
The last Program Key will be assigned with the “Store 4 Poll” Key name automatically
and cannot be changed.
To prepare the document(s) to be polled, simply place the document(s) on the ADF or Platen
and then press the Program Key to store or add the document(s) into a polled file.
(Note: If a regular polled file is stored in memory, the Program Key for Continuous Polling will
not be accepted.)
Note 2:
Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 3:
Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 4:
The default setting of parameters depends on the country’s specifications or regulations. Print the
Function Parameter List to confirm the default settings.
117~
121
Not Used
122 LDAP
1 = Off
2 = On
When LDAP is used, specialized characters may be
displayed as different characters.
123 One Ring Sound
(USA and Canada
Only)
1 = Off
2 = On
(Effective from Sept. 2004
Production)
When Function Parameter No. 45 "Ring Detect
Count" is set to 1 Ring, and this parameter is
enabled (On), the machine will only ring once out
loud, answering on the second ring count.
124 ~
199
Not Used
Signal
Setting
1:128
2:256
3:512
4:1024
5:2048
6:Off
MCF/PIP
0-31
0-63
0-127
0-255
0-511
Always
RTP/PIP
32-63
64-127
128-255
256-511
512-1023
-
RTN/PIN
64-127
128-255
256-511
512-1023 1024-2047
-
Signal
Setting
1:5%
2:10%
3:15%
4:20%
MCF/PIP
0-2
0-4
0-7
0-9
RTP/PIP
3-4
5-9
8-14
10-19
RTN/PIN
5-
10-
15-
20-
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for DP-180
Page 50: ...50 UF 9000 APR 2006 Ver 3 0 DP 180 190 21 Remove the LCD Module 127 ...
Page 74: ...74 UF 9000 APR 2006 Ver 3 0 DP 180 190 3 3 Preventive Maintenance Points ...
Page 126: ...126 UF 9000 APR 2006 Ver 3 0 DP 180 190 Sensor and Switch Location ...
Page 341: ...341 UF 9000 APR 2006 Ver 3 0 DP 180 190 memo ...
Page 343: ...343 APR 2006 Ver 3 0 UF 9000 DP 180 190 memo ...
Page 359: ...Published in Japan ...
Page 375: ...Published in Japan ...