8

The remote zero-adjustment function forcibly sets the pressure value to
“zero” when the external signal is input.
The setting value is not corrected when remote zero-adjustment is input.
Make sure that the pressure and setting value during remote zero-adjust-
ment do not exceed the pressure range that can be set.

Operation charts

The remote zero-adjustment value is cleared when the setting of the
analog voltage output / external input is changed or the power is turned
ON again, and normal operation based on the atmospheric pressure is
resumed.

The remote zero-adjustment value can be confirmed when setting the
threshold value in RUN mode. For details, see page 3, section 9, RUN
MODE.

14

REMOTE ZERO-ADJUSTMENT FUNCTION, 
MULTIFUNCTION TYPE

During normal operation. (Each 
comparative output set to N.O.)

During remote zero-adjustment 
input. (Each comparative out-
put set to N.O.)

• Detected pressure at auto-

reference input: 10kPa

• Output mode: Hysteresis mode

Note:

The setting values shift in the same manner during EASY mode 
or the window comparator mode.

15

ERROR INDICATION

Error

Cause

Corrective action

The load is short circuited 
causing overcurrent.

Turn off the power and 
check the load.

Pressure is being applied 
during zero-adjustment.

Do not apply pressure 
applied at the pressure port; 
pressure should equal atmo-
spheric pressure.
Redo zero-adjustment.

External input is carried out 
outside the rated pressure 
range.

Applied pressure range 
should be adjusted to fall 
within rated pressure range.

Communication error, e.g. 
disconnection, faulty con-
nection, etc.

Check the wiring when using 
the copy function.

Communication error, incor-
rect model.

Make sure the master and 
slave sensors are the same 
model when using the copy 
function.

The applied pressure 
exceeds the upper limit of 
the display pressure range.

Applied pressure range 
should be adjusted to fall 
within rated pressure range.

The applied pressure 
exceeds the lower limit 
(reverse pressure) of the 
display pressure range.

10 20 30 40 50 60

0

10 20 30 40 50 60

0

1

10 20

10 20 30 40 50 60

0

10 20 30 40 50 60

0

P(a)

10 20 30

2

1

2

ON

OFF

Output

Applied pressure (kPa

)

Displayed value (kPa)

Set value (kPa)

ON

OFF

Output

Applied pressure (kPa

)

Displayed value (kPa)

Set value (kPa)

16

MODELS, ORDERING INFORMATION

DP10

-

-

-

1: low pressure type
2: high pressure type

Nil: R1

8+M5 female screw

E: G1

8+M5 female screw

M: M5 female screw
N: NPT1

8+M5 female screw

Nil: standard type
A: high function type

Nil: NPN output type
P: PNP output type

Nil: cable with connector enclosed
J: no cable

Rugghölzli 2

CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for DP-100 series

Page 1: ...ightening a commercial coupler to the pressure port The tightening torque should be 9 8N m or less M5 female connector 1N m or less The commercial coupler or pressure port section will be damaged if the tightening torque is excessive Wrap sealing tape around the coupler when connecting to prevent leaks INSTRUCTION MANUAL WARNING Never use this product as a sensing device for personnel protection I...

Page 2: ...OUNTING No Part Description 1 M3 length 6mm screws with washers Accessory with MS DP1 1 2 Sensor mounting bracket MS DP1 1 Optional 5 WIRING Pin no Terminal name 1 V 2 Comparative output 1 3 Standard type Comparative output 2 Multifunction type Analog voltage output or external input 4 0V 6 I O CIRCUIT DIAGRAMS 1 2 CN 14A C غ Recommended product Contact SPHD 001T P0 5 Housing PAP 04V S JST Mfg Co ...

Page 3: ...when psi is selected as the pressure unit Hi 1 or Lo 1 is displayed for comparative output 1 and Hi 2 or Lo 2 for comparative output 2 on the sub display Notes Hysteresis can be fixed in 8 levels For details see page 6 section 11 PRO MODE Hi 1 or Lo 1 is displayed for comparative output 1 and Hi 2 or Lo 2 for comparative output 2 on the sub display 8 SELECTING MODES 9 RUN MODE Setting condition 1 ...

Page 4: ...put AREF Auto reference input 1 or ZERO Remote zero adjustment input 2 1For details see page 7 section 13 AUTO REFERENCE FUNCTION 2 For details see page 8 section 14 REMOTE ZERO ADJUSTMENT FUNCTION MULTIFUNCTION TYPE Setting condition 3 Comparative output 1 set to HYS Hysteresis mode or WCMP Window comparator mode Analog voltage output external input Analog voltage output Setting condition 4 Compa...

Page 5: ... Selects color of main display Pressure unit selection Selects desired pressure unit 1If for the standard type DP 100 comparative output 2 is set to OFF the N O N C selection normally open normally closed selection is the same as for the multifunction type i e you will only set N O or N C for comparative output 1 not for both comparative outputs 2The default setting of the high pressure type is N ...

Page 6: ... carried out for approx 5s in RUN mode the display is turned off Press any key to temporarily show the normal display Setting check code Current settings for DP 100 are stored in code which you can display See Code table on page 7 Setting copy mode Settings can be copied from master sensors to slave sensors For details see page 7 section 12 SETTING COPY FUNCTION ON settings are copied ON L setting...

Page 7: ...digit 7th digit 8th digit Analog voltage output Compara tive output 1 Compara tive output 1 Compara tive output 1 Compara tive output 1 Compara tive output 2 Compara tive output 2 Compara tive output 2 Compara tive output 2 Remote zero adjustment Auto reference N O OFF OFF N C N O N O N C N C N O N O N C N C N C N O EASY Hysteresis Window comparator EASY Hysteresis Window comparator Red when ON Gr...

Page 8: ...ot apply pressure applied at the pressure port pressure should equal atmo spheric pressure Redo zero adjustment External input is carried out outside the rated pressure range Applied pressure range should be adjusted to fall within rated pressure range Communication error e g disconnection faulty con nection etc Check the wiring when using the copy function Communication error incor rect model Mak...

Page 9: ...igits Repeatability 0 1 F S within 2 digits 0 2 F S within 2 digits 0 1 F S within 2 digits 0 2 F S within 2 digits Response time ms 2 5 5 10 25 50 100 250 500 1000 5000ms selectable Analog voltage output _ Output voltage 1 to 5V Zero point within 3V 5 F S Span within 4V 5 F S Linearity within 1 F S Output impedance approx 1k Output voltage 0 6 to 5V Zero point within 1V 5 F S Span within 4 4V 5 F...

Reviews: