21
7.1.2.
Special Modes Setting
IR ERR
IR communication error
[IR ERR] is displayed when communication
between Timer microprocessor and IR
microprocessor fails.
No display
No REC
Recording is impossible
[No REC] is displayed when recording is
impossible due to the defect, dirt or wound of
media.
No display
HDD
ERROR
[HDD ERR] is displayed
when start up of HDD was
failed.
(Except error of setting of
Power on Stand-by)
a) When normal start up was failed.
b) When start up at HDD boot was failed.
c) When start up from state of P-OFF was
failed.
d) When start up from state of HDD SLEEP
was failed.
[HDD ERR] is displayed when above each
start up of HDD was failed.
*In case b), tray opens automatically and
[HDDERR] is displayed until version up disc
is inserted.
No display
HDD NG
Power on Stand-by setting
error
[HDD NG] is displayed when power on
Standby setting of HDD is NG or when HDD
which power on Stand-by is not set to is
used.
Please try to replace HDD with genuine HDD
as service parts.
No display
Item
FL Display
Key Operation
Mode Name
Description
Front Key
TEST Mode
*All the main unit’s parameters (include
tuner) are initialized.
Press [STOP], [CH UP] and [OPEN/
CLOSE] keys simultaneously for
five seconds when power is off.
Rating password
The audiovisual level setting password is
initialized to “Level 8”.
Open the tray, set DRIVE SELECT
to DVD, and press [REC] and
[PLAY] simultaneously for 5 sec-
onds.
Service Mode
Setting every kind of modes for servicing.
*Details are described in “
7.1.3. Service
Mode at a glance
”.
When the power is off, press [CH
UP], [OPEN/CLOSE] and [REC]
keys simultaneously for 5 seconds.
Forced disc eject
Removing a disc that cannot be ejected.
The tray will open and unit will shift to P-off
mode.
*When Timer REC is ON or EXT-LINK is ON,
execute " Forced disc eject " after releasing
Timer REC or EXT-LINK.
*This command is not effective during "Child
lock" is ON.
While Demonstration Lock is being set, this
Forced disc eject function is not accepted.
The display before execution
leaves.
When the power is off, press
[STOP] and [CH UP] keys simulta-
neously for 5 seconds.
Child lock/unlock
Set or release “Child Lock”.
Press [OK] and [RETURN] by
remote controller simultaneously
until [X-HOLD] is displayed.
NTSC/PAL system select To switch PAL/NTSC alternately.
The display before execution
leaves.
While the power is on (E-E mode),
press [STOP] and [OPEN/CLOSE]
simultaneously for 5 seconds.
Forced power-off
When the power button is not effective while
power is ON, turn off the power forcibly.
*When Timer REC is ON or EXT-LINK is ON,
execute “Forced Power-off” after releasing
Timer REC or EXT-LINK.
Display in P-off mode.
Press [Power] key over than 10
seconds.
Error Code
Diagnosis Contents
Description
Monitor Display
Automatic FL display
Summary of Contents for DMR-EH59GA
Page 5: ...5 1 2 Caution for AC Cord For EH59GC only ...
Page 14: ...14 ...
Page 18: ...18 NOTE Use the replacement parts RMV0335 when the Sheet has not being stickability ...
Page 35: ...35 9 2 P C B Positions ...
Page 42: ...42 10 1 2 Checking and Repairing of RAM Digital P C B Module ...
Page 43: ...43 10 1 3 Checking and Repairing of Main P C B ...
Page 44: ...44 10 1 4 Checking and Repairing of HDD ...
Page 90: ...90 14 1 6 Waveform Chart ...