34
9.7.
Removal of the MOS FPC Unit
When remove the MOS FPC unit once (the screw(E) is loos-
ened even a little), the optical tilt adjustment is required.
When loosen the screw(E), necessary the optical tilt adjustment
at the end of assembling. (Refer to item “10.3.2.”)
To prevent the MOS FPC unit from catching the dust and dirt,
do not remove the MOS FPC unit except for replacing.