Section
Chapter 4. Trunks and Lines
Installing
in
a Double Cabinet with Tls in the Master and
Slave
1.
2.
3.
4.
5.
6.
7.
8.
Install the Sync Unit in the master cabinet as described in Steps and
under “Installation for a Single
Install a
MDF card in each cabinet. (See Step 3 on page 4-23.)
Set Switch 1 on the
cards. (See Step 4 on page 4-24.)
Install a
card in each
slot.
Connect the Clock Sync Cable from CN4 on the master-cabinet to
on the slave-cabinet
as shown in Figure 4-12.
Note:
Part Number VB-43564 is used for the Clock Sync Cable when Tls
are installed in the master and slave cabinets.
At the master cabinet, connect the Sync Cable from
on the Sync
Unit to
on the
card (Figure 4-12).
At each cabinet, connect the cable attached to CN3 on the
MDF card
to CN3 on the
card (Figure 4-10).
Using an RJ48 cable, connect
of each
MDF card to a CSU. (See
Figure 4-9 on page 4-25 for RJ48 pinouts.)
For both cabinets, connect the ground cable from the
MDF card as
shown in Figure 4-10 on page 4-26.
DBS-70-300
Manual Issued
4-29