Section
Chapter 5. Peripheral
Equipment
Table S-11. Maximum
for SLTA installation
Wiring
Max. distance (in feet) between
Max. distance (in feet) between
the DBS and SLTA
the SLTA and the SLT
AWG 22
300’ or 10
3000’ or 100
AWG 24
190’ or 10
1900’ or 100
AWG 26
120’ or 10
1200’ or 100
4.
5.
6.
7.
8.
9.
the DBS is powered up, turn off the power.
Connect the GND and
leads on the SLTA to the DBS connector
panel.
Be sure the wires do not touch each other or touch the metal
frame housing.
Turn on the DBS power.
Connect the “T” and “R” leads to the digital extension ports on
the DBS
as per Figure 5-21. One digital extension port is required for each
SLT.
Connect the SLT “T” and
leads to the
Install the cover on the SLTA.
DBS-70-300
DBS Manual Issued
Summary of Contents for DBS 40
Page 10: ...List of Tables Section 300 installation X DBS Manual Issued 8 l 95 DBS 70 300 ...
Page 13: ...1 2 DES Manual Revised 4 3 96 DES 70 300 ...
Page 19: ...DES Manual Issued 8 l 95 DES 70 300 ...
Page 28: ...3 2 DBS Manual Issued 8 l 95 DES 70 300 ...
Page 47: ...4 2 DBS Manual Issued 8 l 95 DBS 70 300 ...
Page 91: ...5 2 DBS Manual Issued 8 l 95 DBS 70 300 ...
Page 127: ...6 2 DBS Manual Issued 8 l 95 DBS 70 300 ...