background image

ENGLISH

7

•  Wipe the unit gently with a soft, dry 

cloth.

•  It is recommended to clean the air 

fi

 lters once every 2 weeks.

• Purchase the replacement 

fi

 lter if it 

is damaged.

  Part no.: CWD001144

INDOOR UNIT

AIR FILTER

•  It is recommended to clean the 

fi

 lter 

every 6 months.

• Replace the 

fi

 lter every 3 years or 

purchase the replacement 

fi

 lter if it 

is damaged. 

  Part no.: CZ-SA13P

SUPER ALLERU-BUSTER

•  Operate the unit for 2~3 hours using 

heating operation to dry the internal 
parts.

•  Turn off the power supply and unplug.
•  Remove the remote control batteries.

15)%4 0/7%2&5, )/.

4)-%2

0/7%2

Vacuum, wash and dry.

AIR FILTER

AIR FILTER

Clean with cotton 
bud.

IONIZER

IONIZER

FRONT PANEL

FRONT PANEL

Raise and pull to remove. 
Wash and dry.

Remove

Remove

INDOOR UNIT

INDOOR UNIT

Wipe gently.

SUPERSONIC AIR 

SUPERSONIC AIR 

PURIFYING DEVICE

PURIFYING DEVICE

Vacuum the super 
alleru-buster fi lter.

Vacuum, wash and 
dry the frame.

Remove

CARE & CLEANING

Switch off the power supply 

Switch off the power supply 

before cleaning

before cleaning

 Washing Instructions

•  Do not use benzene, thinner or 

scouring powder.

•  Use soaps or neutral household 

detergent ( pH7) only.

•  Do not use water with temperature 

higher than 40°C.

 Preparation for extended 

Non-operation

•  It is recommended to clean the 

ionizer every 6 months.

IONIZER

•  This inspection is recommended 

before operating the air conditioner 
at every season.

•  Check if the remote control batteries 

needed to be replaced.

•  Ensure there is no obstruction at all 

air intake and outlet vents.

•  After the start of operation for 15 

minutes, it is normal if the 
temperature differences between 
air intake and outlet vents at indoor 
unit is:-

Operation

Temperature

Cooling

 8°C

Heating

 14°C

 Pre-season Inspection

 Clean the 

fi

 lter regularly as dirty 

fi

 lters will cause unpuri

fi

 ed air, low cooling or heating capacity, unpleasant smells and higher 

energy consumption.

  The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an 

authorized dealer to perform seasonal inspections in addition to regular cleaning.

  This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner 

from being damaged by abnormally strong lightning activity, you may switch off the power supply. 

Hints

Summary of Contents for CS-W7DKR

Page 1: ...R CU W9DKR CS W12DKR CU W12DKR Manufactured by Panasonic HA Air Conditioning M Sdn Bhd Lot 2 Persiaran Tengku Ampuan Section 21 Shah Alam Industrial Site 40300 Shah Alam Selangor Malaysia ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference 2 7 ...

Page 2: ...n of the remote control In case of emergency or abnormal condition burnt smell etc occurs turn off the power supply and unplug Do not share power outlet Do not modify power cord Do not use an extension cord Do not operate with wet hands Do not operate or stop the unit by inserting or pulling out the power plug Do not insert finger or other objects into the indoor or outdoor unit Do not attempt to ...

Page 3: ...beep OFF short beep ON Auto OFF ON Button 1 Pull out 2 Insert batteries AAA or R03 3 Press CLOCK button 4 Set current time 5 Press again to confirm Troubleshooting Operation delayed for few minutes after restart This is a normal self protection control Sound like water flowing during operation Caused by refrigerant flow inside Mist emerges from indoor unit Condensation effect due to cooling proces...

Page 4: ... and Ion operations could be activated in all operation modes Press OFF ON button again to stop the operation Operation Details The unit will automatically select the operation mode according to the room temperature Once the operation mode is selected the unit will operate at the standard setting temperature as shown Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C...

Page 5: ... swings up and down automatically Please do not adjust the vertical airflow direction louver manually Horizontal airflow direction louver could be adjusted manually AIR SWING Ion operation could be activated independently Powerful and Quiet operations could not be activated at the same time Powerful Quiet and Ion operations could be cancelled by pressing the respective button again HOW TO OPERATE ...

Page 6: ...nditioner operation at the desired time This can save electricity while you are going out or sleeping The set timer will repeat daily once it is set If there is a power failure you can press SET button to restore the previous setting once the power is resumed If the timer is cancelled you can restore the previous setting by pressing SET button TIMER Press CLOCK more than 10 seconds to change the t...

Page 7: ...hinner or scouring powder Use soaps or neutral household detergent pH7 only Do not use water with temperature higher than 40 C Preparation for extended Non operation It is recommended to clean the ionizer every 6 months IONIZER This inspection is recommended before operating the air conditioner at every season Check if the remote control batteries needed to be replaced Ensure there is no obstructi...

Page 8: ...orized Distributor under the following conditions Abnormal noise during operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power plug cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS ...

Reviews: