background image

2

(GB Standard)

red

black

green/yellow

Operation Condition (°C)

Use this air conditioner under the following temperature 
range.

DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature

Indoor

Outdoor

DBT

WBT

DBT

WBT

Maximum Temperature (COOL)

32

23

43

26

Maximum Temperature (HEAT)

30

24

18

Minimum Temperature (COOL)

16

11

16

11

Minimum Temperature (HEAT)

16

-5

-6

This sign warns of death 

or serious injury.

The appliance is not intended for use by young children or in

fi

 rm 

person without supervision. Young children should be supervised to 
ensure that they do not play with the appliance.

Replacement or installation of power plugs shall be performed by 
authorized/quali

fi

 ed personnel only. The wires in this mains lead are 

coloured in accordance with the following code:

To prevent personal injury, 
injury to others and property 
damage, the following 
instructions must be 
followed.

Incorrect operation due to 
failure to follow instructions 
will cause harm or damage, 
the seriousness of which is 
classi

fi

 ed as below:

This symbol denotes 

an action that is 

PROHIBITED.

These symbols denote 

actions that are 

COMPULSORY.

Warning

 Definition

This sign warns of injury 

or damage to property.

Caution

The instructions to be 
followed are classi

fi

 ed by 

the following symbols:

Safety Regulation

Thank you for purchasing Panasonic Air Conditioner

Caution

Warning

•  Insert the power plug properly.
• Use 

speci

fi

 ed supply cord.

•  If the supply cord is damaged or needed 

to be replaced, it must be replaced by 

the manufacturer or its service agent or 

a similarly quali

fi

 ed person in order to 

avoid a hazard.

•  Remove the batteries if the unit is not 

going to be used for a long period of 

time.

•  New batteries of the same type must 

be inserted following the polarity stated 

to prevent malfunction of the remote 

control.

•  In case of emergency or abnormal 

condition (burnt, smell, etc) occurs, turn 

off the power supply and unplug.

•  Do not share power outlet.
•  Do not modify power cord.
•  Do not use an extension cord.
•  Do not operate with wet hands.
•  Do not operate or stop the unit by inserting 

or pulling out the power plug.

•   Do not insert 

fi

 nger or other objects into 

the indoor or outdoor unit.

•  Do not attempt to repair the unit by 

yourself.

•  Do not use rechargeable (Ni-Cd) batteries.
•  Keep the remote control away from infants 

and small children to prevent them from 

accidentally swallowing the batteries.

•  Do not pull the cord to 

disconnect the plug.

•  Do not wash the unit with water, benzene, 

thinner or scouring powder.

•   Do not use for other purposes such as 

preservation of food.

•  Do not use any combustible equipment at 

air

fl

 ow direction.

•  Do not sit or place anything on the indoor 

or outdoor unit.

•  Do not expose directly to cold air for a 

long period.

•  Ventilate the room regularly.
•  Pay attention as to whether the 

installation rack is damaged after long 
period of usage.

•  Switch off the power supply and unplug 

before cleaning or servicing.

•  Turn off the power supply and unplug if 

the unit is not used for a long period of 
time.

SAFETY PRECAUTIONS

Operation Precautions

Operation Precautions

Different countries may have different colour coding for the wires.

Warning

Installation Precautions

Installation Precautions

Do not install, remove and reinstall the unit by yourself.
•  Improper installation will cause leakage, electric shock or 

fi

 re. Please consult an authorized dealer or 

specialist for the installation work.

•  This equipment must be earthed and installed with ELCB. It may cause electrical shock or 

fi

 re in case of 

malfunction.

Caution

•  This air conditioner must be earthed. Improper grounding will cause electric shock.
•  Ensure that the drainage piping is connected properly. Otherwise, water will leak.

•  Do not install the unit in a potentially explosive atmosphere.

Summary of Contents for CS-W7DKR

Page 1: ...R CU W9DKR CS W12DKR CU W12DKR Manufactured by Panasonic HA Air Conditioning M Sdn Bhd Lot 2 Persiaran Tengku Ampuan Section 21 Shah Alam Industrial Site 40300 Shah Alam Selangor Malaysia ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference 2 7 ...

Page 2: ...n of the remote control In case of emergency or abnormal condition burnt smell etc occurs turn off the power supply and unplug Do not share power outlet Do not modify power cord Do not use an extension cord Do not operate with wet hands Do not operate or stop the unit by inserting or pulling out the power plug Do not insert finger or other objects into the indoor or outdoor unit Do not attempt to ...

Page 3: ...beep OFF short beep ON Auto OFF ON Button 1 Pull out 2 Insert batteries AAA or R03 3 Press CLOCK button 4 Set current time 5 Press again to confirm Troubleshooting Operation delayed for few minutes after restart This is a normal self protection control Sound like water flowing during operation Caused by refrigerant flow inside Mist emerges from indoor unit Condensation effect due to cooling proces...

Page 4: ... and Ion operations could be activated in all operation modes Press OFF ON button again to stop the operation Operation Details The unit will automatically select the operation mode according to the room temperature Once the operation mode is selected the unit will operate at the standard setting temperature as shown Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C...

Page 5: ... swings up and down automatically Please do not adjust the vertical airflow direction louver manually Horizontal airflow direction louver could be adjusted manually AIR SWING Ion operation could be activated independently Powerful and Quiet operations could not be activated at the same time Powerful Quiet and Ion operations could be cancelled by pressing the respective button again HOW TO OPERATE ...

Page 6: ...nditioner operation at the desired time This can save electricity while you are going out or sleeping The set timer will repeat daily once it is set If there is a power failure you can press SET button to restore the previous setting once the power is resumed If the timer is cancelled you can restore the previous setting by pressing SET button TIMER Press CLOCK more than 10 seconds to change the t...

Page 7: ...hinner or scouring powder Use soaps or neutral household detergent pH7 only Do not use water with temperature higher than 40 C Preparation for extended Non operation It is recommended to clean the ionizer every 6 months IONIZER This inspection is recommended before operating the air conditioner at every season Check if the remote control batteries needed to be replaced Ensure there is no obstructi...

Page 8: ...orized Distributor under the following conditions Abnormal noise during operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power plug cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS ...

Reviews: