4
●
To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in.
Hint
●
The room has a peculiar odour.
➤
This may be a damp smell emitted by the wall, carpet, furniture or
clothing in the room.
●
Air conditioner does not cool or heat ef
fi
ciently.
➤
Ensure the temperature has been set correctly.
➤
Ensure windows and doors have been closed properly.
➤
Ensure
fi
lters are cleaned or replaced when necessary.
➤
Ensure inlet and outlet vents of the units have not been obstructed.
●
In heating operation, power indicator blinking and no
warm air discharge.
➤
Defrost operation at outdoor unit, maximum 12 minutes.
Troubleshooting
AUTO
COOL
HEAT
DRY
Auto, Heat, Cool, Dry
Auto, Heat, Cool, Dry
2
2
Select the
desired
operation.
3
3
Set the
temperature.
Start the
operation.
1
1
HOW TO OPERATE
●
Supersonic air purifying device (super alleru-buster) operates
automatically while the air conditioner is switched on.
●
Powerful, Quiet and Ion operations could be activated in all
operation modes.
●
Press
OFF/ON
button again to stop the operation.
■
Operation Details
• The unit will automatically select the
operation mode according to the
room temperature.
• Once the operation mode is
selected, the unit will operate at the
standard setting temperature as
shown:
Room
temperature
Operation
mode
Standard
setting
temperature
23°C & above
Cool
25°C
Below 23°C
Dry
22°C
Below 20°C
Heat
21°C
• You may press
or
button
to change the standard setting
temperature to “HI” or “LO” as
shown:
Operation mode
HI
LO
Cool
27°C
23°C
Dry
24°C
20°C
Heat
23°C
19°C
• Enables you to enjoy the cooling
effect at your preferred setting
temperature.
• The range of temperature can be
selected from 16°C ~ 30°C.
• Enables you to set the desired
temperature at low fan speed which
provides you with the dehumidifying
surroundings.
• The range of temperature can be
selected from 16°C ~ 30°C.
AUTO - Automatic Operation
COOL - Cooling Operation
DRY - Soft Dry Operation
• Enables you to enjoy the warming
effect at your preferred setting
temperature.
• The range of temperature can be
selected from 16°C ~ 30°C.