1.
This equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
1. Selection of the installation location.
Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
2.
Power supply connection to the room air conditioner.
Connect the power supply cord of the room air conditioner to the mains using one of the following method.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1.
Power supply connection to the receptacle using a power plug.
Use an approved 16A power plug with earth pin for 2.0HP (V18CK, W18CK) and 20A for 2.5HP (V24CK, W24CK) for the connection
to the receptacle.
2.
Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker 2.0HP (V18CK,
W18CK) and 20A for 2.5HP (V24CK, W24CK) for the permanent connection. It must be a double pole switch with a minimum 3 mm
contact gap.
3.
Do not release refrigerant.
Do not release refrigerant during piping work for installation, reinstallation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
4.
Installation work.
It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
44
CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE
Summary of Contents for CS-W18CKE
Page 10: ...4 Dimensions 10 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 11: ...11 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 13: ...6 Block Diagram 13 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 14: ...7 Wiring Diagram CS W18CKE CU W18CKE CS W24CKE CU W24CKE 14 ...
Page 34: ...34 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 36: ...39 40 41 38 36 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 37: ...39 37 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 38: ...35 37 38 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 39: ...38 39 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 40: ...39 40 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 41: ...41 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 70: ...14 Technical Data 70 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 72: ...72 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 73: ...73 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 82: ...SCHEMATIC DIAGRAM 5 5 82 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 84: ...19 1 REMOTE CONTROL 84 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...