![Panasonic CS-W18CKE Service Manual Download Page 2](http://html.mh-extra.com/html/panasonic/cs-w18cke/cs-w18cke_service-manual_1508191002.webp)
11.2. TOOLS FOR INSTALLING/SERVICING REFRIGERANT
PIPING
54
11.3. REFRIGERANT PIPING WORK
58
11.4. INSTALLATION, TRANSFERRING, SERVICING
60
12 Servicing Information
64
12.1. Indoor Electronic Controllers Removal Procedures
64
12.2. Cross Flow Fan Indoor and Fan Motor Removal
Procedures
65
13 Troubleshooting Guide
68
13.1. Refrigeration cycle system
68
14 Technical Data
70
15 Exploded View
74
16 Replacement Parts List
75
17 Exploded View
76
18 Replacement Parts List
77
•
•
•
•
High Efficiency
•
•
•
•
Compact Design
•
•
•
•
Comfort Environment
−
−
−
−
Ionizer control for generate negative ion in discharge air
−
−
−
−
Air filter with function to reduce dust and smoke
−
−
−
−
Wider range of horizontal discharge air
−
−
−
−
New Automatic air swing and manual adjusted by
remote control for horizontal airflow.
•
•
•
•
Auto Restart
−
−
−
−
Random auto restart after power failure for safety restart
operation
•
•
•
•
Removable and Washable Front Panel
•
•
•
•
Remote Control Self-illuminating Button
•
•
•
•
Catechin Air Purifying Filter
−
−
−
−
Trap dust, tobacco smoke and tiny particles
−
−
−
−
Prevent the growth of bacteria and viruses trapped
•
•
•
•
Triple Deodorizing Filter
−
−
−
−
Absorb odours produced by wall paper, construction
material and living environment
19 Electronic Circuit Diagram
78
19.1. REMOTE CONTROL
84
19.2. PRINT PATTERNINDOOR UNIT PRINTED CIRCUIT
BOARD
TOP VIEW
85
19.3. PRINT PATTERNINDOOR UNIT PRINTED CIRCUIT
BOARD
BOTTOM VIEW
86
19.4. PRINT PATTERNOUTDOOR UNIT PRINTED CIRCUIT
BOARD
87
•
•
•
•
Quality Improvement
−
−
−
−
Gas leakage protection
−
−
−
−
Prevent compressor reverse cycle
−
−
−
−
Inner protector
−
−
−
−
Noise prevention during soft dry operation.
−
−
−
−
Anti-dew Formation Control (Cooling & Soft Dry)
−
−
−
−
Overload Protection Control (Heating)
−
−
−
−
Outdoor Fan Control
−
−
−
−
Compressor High Pressure Control
−
−
−
−
Blue Coated Condenser
−
−
−
−
High resistance to corrosion.
•
•
•
•
Operation Improvement
−
−
−
−
Quiet mode to provide quiet operation
−
−
−
−
Powerful mode to reach the desired room temperature
quickly
•
•
•
•
Long Installation Piping
−
−
−
−
Long piping up to 25 meter
•
•
•
•
24-hour Timer Setting
•
•
•
•
Environmental Friendly
−
−
−
−
R410A, which does not contain chlorine, is used as its
refrigerant, so there is no danger of damage to the
ozone layer in stratosphere.
1 Features
2
CS-W18CKE CU-W18CKE / CS-W24CKE CU-W24CKE
Summary of Contents for CS-W18CKE
Page 10: ...4 Dimensions 10 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 11: ...11 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 12: ...5 Refrigeration Cycle Diagram 12 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 13: ...6 Block Diagram 13 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 14: ...7 Wiring Diagram CS W18CKE CU W18CKE CS W24CKE CU W24CKE 14 ...
Page 34: ...34 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 36: ...39 40 41 38 36 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 37: ...39 37 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 38: ...35 37 38 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 39: ...38 39 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 40: ...39 40 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 41: ...41 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 70: ...14 Technical Data 70 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 72: ...72 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 73: ...73 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 82: ...SCHEMATIC DIAGRAM 5 5 82 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...
Page 84: ...19 1 REMOTE CONTROL 84 CS W18CKE CU W18CKE CS W24CKE CU W24CKE ...