OPERATING INSTRUCTIONS ( 8 / 11 )

CODE NO.

ACXF55-18700

12

AIR CONDITIONER

ON

OFF

SET

TIMER

CANCEL

OFF/ON

FAN SPEED

MODE

SLEEP

QUIET

AIR SWING

TEMP

OFF/ON

How to use

Not used 

in normal 

operations.

Press to restore 

the remote 

control to default 

setting.

Indicator

POWER

TIMER

i AUTO-X

nanoe-G

ECONAVI

To adjust vertical air

À

 ow direction

Upper direction

Lateral direction

AIR SWING

• Do not adjust the 

À

 ap by hand.

To adjust fan speed

AUTO

FAN

FAN SPEED

• For AUTO, the indoor fan speed is automatically 

adjusted according to the operation mode.

• If i AUTO-X mode is set, fan speed is 

¿

 xed to AUTO. 

To adjust fan speed, cancel i AUTO-X mode.

To purify the air

• nanoe-G starts automatically when the unit is turned 

on with 

OFF/ON

OFF/ON

 .

• nanoe-G will not start automatically during ON timer 

if the unit has been turned off by 

OFF/ON

OFF/ON

 .

• Can be activated even when the unit is turned off. 

In this condition, the unit will operate as a fan with 
AUTO fan speed and 

À

 ap swing.

To enjoy quiet operation

QUIET

• This operation reduces air

À

 ow noise.

To save energy

• When manual AIR SWING 

 is selected, the 

ECONAVI operations will be cancelled.

13

English

How to use

To set the timer

Note

 , 

SLEEP

 , 

 , 

QUIET

 , 

• Can be activated in all modes and can be 

cancelled by pressing the respective button 

again.

• Cannot be selected at the same time.

ON

OFF

SET

TIMER

CANCEL

CANCEL

2

1

3

1

Select ON or OFF 

timer

Example: 

OFF at 22:00

• Each time pressed:

OFF

Cancel

2

Set the time

3

Con

¿

 rm

SET

• To cancel ON or OFF timer, press 

ON

 or 

OFF

 

to select respective   or   then press 

CANCEL

.

• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 

pressing 

ON

 or 

OFF

 to select respective   or 

 then press 

SET

.

• The nearest timer setting will be displayed and 

will activate in sequence.

• Timer operation is based on the clock set in the 

remote control and repeats daily once set. For 

clock setting, please refer to Quick Guide.

2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset 

times.

• The unit controls set temperature according to room temperature to accelerate room cooling.

• After max 4 hours, the set temperature follows the last set temperature setting.

• Fan speed is 

¿

 xed at AUTO, fan speed selection is prohibited.

• During unit is off, press 

 will turn on the unit with i AUTO-X mode.

• i AUTO-X mode can be cancelled by pressing the respective button again.

• This operation provides you with a comfortable environment while sleeping. It will automatically 

adjust the sleep pattern temperature during the activation period.

• The indoor unit indicator will dim when this operation is activated. This is not applicable if 

the indicator brightness has been manually dimmed.

• This operation is incorporated with the activation timer (0.5, 1, 2, 3, 4, 5, 6, 7, 8 or 9 hours). 

• This operation can be set together with timer. Sleep operation has the priority over OFF timer.

• This operation can be cancelled by pressing the respective button when the sleep timer 

reaches 0.0h.

To reach temperature quickly

i AUTO-X

Set temperature

-1°C / 
-2°F

Max = 4 hours

To maximise comfort while sleeping

(CANCEL)

SLEEP

Summary of Contents for CS-U12UKY

Page 1: ...ist refer to technical manual DSA R009 This part should practice first in first out FIFO management SAFETY PART C EN Sym Date Revision Signed Checked AA NOV 22 17 New release Scale Written Checked Checked Approved Authorized NAME OPERATING INSTRUCTIONS 1 11 CODE NO ChiewSF Baizura WeeFL J Terauchi NOV 22 17 NOV 22 17 NOV 22 17 NOV 22 17 ACXF55 18700 Finish Staple Binding 210 148 Front Page Brand N...

Page 2: ...ct Please see the Panasonic website for further information on collection centers etc http www panasonic com in corporate sustainability panasonic india i recycle program html WARNING This symbol shows that this equipment uses a Àammable refrigerant If the refrigerant is leaked together with an external ignition source there is a possibility of ignition This symbol shows that the Operation Instruc...

Page 3: ...sor Area Search Activity Detection Absence Detection AIR CONDITIONER ON OFF SET TIMER CANCEL OFF ON FAN SPEED MODE SLEEP QUIET AIR SWING TEMP OFF ON AIR CONDITIONER ON OFF TIMER CANCEL FAN SPEED SLEEP QUIET AIR SWING A B 3 English Table of contents Safety precautions 4 11 How to use 12 13 To learn more 14 15 Cleaning instructions 16 Troubleshooting 17 19 Information Back Cover B Basic operation 1 ...

Page 4: ...r Ż Complete wire without joining Ż Ż Approved connecting means for example approved socket and plug Complete wire without joining Power Supply OR Indoor Unit Outdoor Unit If the supply cord is damaged it must be replaced by the manufacturer service agent or similarly quali ed persons in order to avoid a hazard It is strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or R...

Page 5: ...n handling of cylinders charging leak detection recovery and disposal and c Able to understand and to apply in practice the requirements in the national legislation regulations and Standards and d Continuously undergo regular and further training to maintain this expertise 7 English Safety precautions 1 Installation Space Product with Àammable refrigerants shall not be installed in an unventilated...

Page 6: ...damage to cables excessive number of connections terminals not made to original speci cation damage to seals incorrect tting of glands etc Ensure that apparatus is mounted securely Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of Àammable atmospheres Replacement parts shall be in accordance with the manufacturer s spec...

Page 7: ...the system when charging is complete if not already Extreme care shall be taken not to over ll the refrigeration system Prior to recharging the system it shall be pressure tested with OFN refer to 7 The system shall be leak tested on completion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site Electrostatic charge may accumulate and create ...

Page 8: ... or OFF timer Example OFF at 22 00 Each time pressed OFF Cancel 2 Set the time 3 Con rm SET To cancel ON or OFF timer press ON or OFF to select respective or then press CANCEL If timer is cancelled manually or due to power failure you can restore the timer again by pressing ON or OFF to select respective or then press SET The nearest timer setting will be displayed and will activate in sequence Ti...

Page 9: ...G deactivates viruses bacteria on the lter for 2 hours with fan stopped and Àap closed Do not turn off the power supply during this operation After power failure this operation will not resume Operating conditions Use this air conditioner in the temperature range indicated in the table Temperature C F Indoor Outdoor DBT WBT DBT WBT COOL Max 32 89 6 23 73 4 46 114 8 26 78 8 Min 16 60 8 11 51 8 16 6...

Page 10: ... is set the unit may start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time TIMER indicator is always on The timer setting repeats daily once set Operation is delayed a few minutes after restarting The delay is a protection to the unit s compressor Indoor fan stops occasionally during automatic fan speed setting This helps to remove the surrou...

Page 11: ...ity H 26 Minus ION abnormality H 27 Outdoor air temperature sensor abnormality H 28 Outdoor heat exchanger temperature sensor 1 abnormality H 30 Outdoor discharge pipe temperature sensor abnormality H 31 Abnormal swimming pool sensor H 32 Outdoor heat exchanger temperature sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 ...