12 Operation and Control
12.1. Basic Function
Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes,
automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the
microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature
shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that
judging the condition according to internal setting temperature and intake air temperature.
12.1.1.
Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting processes. These
shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value will be used
as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit.
12.1.2.
Cooling Operation
12.1.2.1. Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5
q
C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point +0.5
q
C.
12.1.3.
Soft Dry Operation
12.1.3.1. Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2
q
C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature > Compressor OFF
point +0.5
q
C.
12.1.4.
Heating Operation
12.1.4.1. Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature > +1.5
q
C.
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature < Compressor OFF
point -0.5
q
C.
Summary of Contents for CS-TE15HKE
Page 8: ...8 5 Dimensions 5 1 Indoor Unit...
Page 9: ...9 5 2 Outdoor Unit...
Page 10: ...10 6 Refrigeration Cycle Diagram...
Page 11: ...11 7 Block Diagram...
Page 12: ...12 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 13: ...13 8 2 Outdoor Unit...
Page 14: ...14 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 15: ...15 9 2 Outdoor Unit...
Page 16: ...16 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Printed Circuit Board...
Page 17: ...17 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board...
Page 20: ...20 3 For the embedded piping This can be used for left rear piping and left bottom piping also...
Page 43: ...43 16 1 2 Removal of Electronic Controller...
Page 44: ...44 16 1 3 Removal of Control Board...
Page 45: ...45 16 1 4 Removal of Fan Motor and Cross Flow Fan...
Page 46: ...46...
Page 48: ...48 17 Technical Data 17 1 Operation Characteristics...
Page 49: ...49...
Page 50: ...50...
Page 51: ...51...