18
11 Installation Instruction
11.1. Select The Best Location
INDOOR UNIT
• Do not install the unit in excessive oil fume area such as
kitchen, workshop and etc.
• There should not be any heat source or steam near the unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling,
fence or other obstacles.
• Recommended installation height for indoor unit shall be at
least 2.5 m.
OUTDOOR UNIT
• If an awning is built over the unit to prevent direct sunlight or
rain, be careful that heat radiation from the condenser is not
obstructed.
• There should not be any animal or plant which could be
affected by hot air discharged.
• Keep the spaces indicated by arrows from wall, ceiling,
fence or other obstacles.
• Do not place any obstacles which may cause a short circuit
of the discharged air.
• If piping length is over the rated length, additional refrigerant
should be added as shown in the table.
Example: For TE9HKE
If the unit is installed at 10 m distance, the quantity of additional
refrigerant should be 50g ...... (10 - 7.5) m x 20 g/m = 50 g
11.2. Indoor/Outdoor Unit
Installation Diagram
Piping size
Rated
Length
(m)
Max
Elevation
(m)
Min.
Piping
Length
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Model
Gas Liquid
TE9HKE 3/8” 1/4”
7.5
15
3
15
20
TE12HKE,
TE15HKE
1/2” 1/4”
7.5
15
3
15
20
Summary of Contents for CS-TE15HKE
Page 8: ...8 5 Dimensions 5 1 Indoor Unit...
Page 9: ...9 5 2 Outdoor Unit...
Page 10: ...10 6 Refrigeration Cycle Diagram...
Page 11: ...11 7 Block Diagram...
Page 12: ...12 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 13: ...13 8 2 Outdoor Unit...
Page 14: ...14 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 15: ...15 9 2 Outdoor Unit...
Page 16: ...16 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Printed Circuit Board...
Page 17: ...17 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board...
Page 20: ...20 3 For the embedded piping This can be used for left rear piping and left bottom piping also...
Page 43: ...43 16 1 2 Removal of Electronic Controller...
Page 44: ...44 16 1 3 Removal of Control Board...
Page 45: ...45 16 1 4 Removal of Fan Motor and Cross Flow Fan...
Page 46: ...46...
Page 48: ...48 17 Technical Data 17 1 Operation Characteristics...
Page 49: ...49...
Page 50: ...50...
Page 51: ...51...