19
11.3. Indoor Unit
11.3.1.
HOW TO FIX INSTALLATION PLATE
The mounting wall is strong and solid enough to prevent it from
the vibration.
The centre of installation plate should be at more than 450 mm
at right of the wall.
The centre of installation plate should be at more than 450 mm
at left of the wall.
The distance from installation plate edge to ceiling should more
than 66 mm.
From installation plate left edge to unit’s left side is 20 mm.
From installation plate right edge to unit’s right is 70 mm.
1. Mount the installation plate on the wall with 5 screws or
more.
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
• Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• The center of the right piping hole is at the intersection of
lines extending vertically from the edge of the installation
plate and horizontally from the sideways arrow on the
installation plate (see figure above).
• The center of the left piping hole is at the intersection of
lines extending vertically from the downward arrow on
the installation plate and horizontally from the sideways
arrow on the installation plate (see figure above).
• Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
11.3.2.
TO DRILL A HOLE IN THE WALL
AND INSTALL A SLEEVE OF
PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the
wall.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
11.3.3.
INDOOR UNIT INSTALLATION
1. For the right rear piping
2. For the right and right bottom piping
: For left side piping, piping connection for liquid should be this
line.
: For left side piping, piping connection for gas should be about
50 mm from this line.
: For left side piping, piping connection cable should be about
750 mm from this line.
Caution
When the wall is hollow, please be sure to use the
sleeve for tube ass’y to prevent dangers caused by
mice biting the connecting cable.
Summary of Contents for CS-TE15HKE
Page 8: ...8 5 Dimensions 5 1 Indoor Unit...
Page 9: ...9 5 2 Outdoor Unit...
Page 10: ...10 6 Refrigeration Cycle Diagram...
Page 11: ...11 7 Block Diagram...
Page 12: ...12 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 13: ...13 8 2 Outdoor Unit...
Page 14: ...14 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 15: ...15 9 2 Outdoor Unit...
Page 16: ...16 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Printed Circuit Board...
Page 17: ...17 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board...
Page 20: ...20 3 For the embedded piping This can be used for left rear piping and left bottom piping also...
Page 43: ...43 16 1 2 Removal of Electronic Controller...
Page 44: ...44 16 1 3 Removal of Control Board...
Page 45: ...45 16 1 4 Removal of Fan Motor and Cross Flow Fan...
Page 46: ...46...
Page 48: ...48 17 Technical Data 17 1 Operation Characteristics...
Page 49: ...49...
Page 50: ...50...
Page 51: ...51...