14.1.2 Relationship between the condition of the air conditioner and pressure and electric
current
Cooling Mode
Heating Mode
Condition of the
air conditioner
Low Pressure
High
Pressure
Electric current
during
operation
Low Pressure
High
Pressure
Electric current
during operation
Insufficient
refrigerant
(gas leakage)
Clogged capillary
tube or strainer
Short circuit in the
indoor unit
Heat radiation
deficiency
of the outdoor unit
Inefficient
compression
• Carry out the measurement of pressure, electric current, and temperature fifteen minutes after an operation is
started.
14.2 Breakdown Self Diagnosis Function
14.2.1 About Self Diagnosis
When the air-conditioner is stopped due to malfunction detected by itself, the operation can be restarted using AUTO
Switch on the indoor unit. In forced operation, the frequency for compressor and fan speed can not be changed and
the signal receiving sound is different.
Normal Operation ON: “pep”
Forced Operation ON: “pep”, “pep”, “pep”, “pep”
Stop: “pep”
Note: Refer to the Diagnosis Code Table for the malfunction when forced operation is not available.
14.2.2 Display of Error Code
1. Keeping the CHECK button on the remote controller depressed for 5 seconds, error code ranging from H11 to H99
can be displayed on the remote controller.
2. The error code is changed and diagnosis signal is transmitted to the indoor unit by pressing the Temp Up button
on the remote control.
3. When the malfunction of the air-conditioner matches the error code on the remote control, four beeps can be heard
from the indoor unit and the operation indicator will light up.
4. Keep the CHECK button depressed continuously for 5 seconds to cancel the diagnosis function.
Summary of Contents for CS-RE12NKR
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Unit mm ...
Page 10: ...10 5 2 Outdoor Unit Unit mm ...
Page 11: ...11 6 Refrigeration Cycle Diagram COOLIN HEATING ...
Page 12: ...12 7 Block Diagram ...
Page 13: ...13 8 Wiring Diagram CS RE9NKR CU RE9NKR ...
Page 14: ...14 CS RE12NKR CU RE12NKR ...
Page 15: ...15 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board ...
Page 18: ...18 10 2 3 Indoor Unit Installation ...
Page 44: ...44 Cooling Characteristic at Different Piping Length ...
Page 45: ...45 Heating Characteristic at Different Outdoor Air Temperature ...
Page 46: ...46 Heating Characteristic at Different Piping Length ...
Page 47: ...47 16 1 2 CS RE12NKR CU RE12NKR Cooling Characteristic at Different Outdoor Air Temperature ...
Page 48: ...48 Cooling Characteristic at Different Piping Length ...
Page 49: ...49 Heating Characteristic at Different Outdoor Air Temperature ...
Page 50: ...50 Heating Characteristic at Different Piping Length ...
Page 51: ...51 17 Exploded View and Replacement Pars List 17 1 Indoor Unit CS RE9NKR CS RE12NKR ...