25
12. Operation Control
12.1 Basic Function
12.1.1 Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting
processes. These shifting processes are depending on the air conditioner settings and the operation environment.
The final shifted value will be used as internal setting temperature and it is updated continuously whenever the
electrical power is supplied to the unit.
12.1.2 Cooling Operation
12.1.2.1
Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5
℃
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature >
Compressor OFF point +0.5K.
12.1.3 Soft Dry Operation
12.1.3.1
Thermostat control
• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -2.5
℃
• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature >
Compressor OFF point +0.5K.
Remote Control Setting Temp. (16
℃
~30
℃
)
Auto operation Mode Shifting
Internal Setting Temperature
Setting Temperature Limit Checking (Min.:
16
℃
~Max.:30
℃
)
Powerful Temperature Shifting
Fan speed Shifting
Dry mode Shifting
Cooling/Heating Shifting
Setting Temperature Limit Checking(Min:
16
℃
; Max.: 33
℃
)
Summary of Contents for CS-RE12NKR
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Unit mm ...
Page 10: ...10 5 2 Outdoor Unit Unit mm ...
Page 11: ...11 6 Refrigeration Cycle Diagram COOLIN HEATING ...
Page 12: ...12 7 Block Diagram ...
Page 13: ...13 8 Wiring Diagram CS RE9NKR CU RE9NKR ...
Page 14: ...14 CS RE12NKR CU RE12NKR ...
Page 15: ...15 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board ...
Page 18: ...18 10 2 3 Indoor Unit Installation ...
Page 44: ...44 Cooling Characteristic at Different Piping Length ...
Page 45: ...45 Heating Characteristic at Different Outdoor Air Temperature ...
Page 46: ...46 Heating Characteristic at Different Piping Length ...
Page 47: ...47 16 1 2 CS RE12NKR CU RE12NKR Cooling Characteristic at Different Outdoor Air Temperature ...
Page 48: ...48 Cooling Characteristic at Different Piping Length ...
Page 49: ...49 Heating Characteristic at Different Outdoor Air Temperature ...
Page 50: ...50 Heating Characteristic at Different Piping Length ...
Page 51: ...51 17 Exploded View and Replacement Pars List 17 1 Indoor Unit CS RE9NKR CS RE12NKR ...