Model   

 
 

 CS-RE9NKR

         CU-RE9NKR

 
 

 CS-RE12NKR

          CU-RE12NKR

COOL

HEAT

COOL

HEAT

Single, 230V-240V, 50Hz

Single, 230V-240V, 50Hz

 

 Power/Current    

[kW]

0.650-0.650 0.810-0.810 0.940-0.940 1.100-1.100

[A]

3.10-3.05

3.80-3.75

4.20-4.10

5.00-4.90

 

  Refrigerant   

[k

g

]

R410A

0.740

R410A

0.970

 

 Cooling Capacity   

[kW]

2.50-2.50

3.50-3.50

 

 

Heating Capacity   

[kW]

3.30-3.30

4.25-4.25

Noise Level   

JIS C 9612 [<70 dB(A)]

[dB(A)]

    

42

42

42

42

Conditions 1m Distance 

Max. cooling

 

47

48

48

50

Sound power level

[dB(A)]

    

58

58

58

58

 

63

64

64

66

 

 Air Circulation   

[m

3

/min.]

12.4

12.1

12.7

12.4

 

 Product Weight   

[k

g

]

    

8.0

8.0

 

25

27

 

 Dimensions (H × W × D)

[mm]

    

290 × 848 × 213

290 × 848 × 213

 

540 × 780 × 289

540 × 780 × 289

1. Standard piping length: 5m(Indoor Unit piping length is not included).

2. Air filters are attached.

 

 
 

Indoor Unit   
Outdoor Unit   

PRODUCT SPECIFICATION

F568478_cover.indd   22

2012-6-4   10:42:02

Summary of Contents for CS-RE12NKR

Page 1: ...KR CS RE12NKR CU RE12NKR Operating Instructions Air Conditioner Indoor Unit Outdoor Unit CS RE9NKR CU RE9NKR CS RE12NKR CCU RE12NKR Print ed in China F568 478 F120 4 00 MOD E AUTO HEAT DRY COO L Select the desire d mode 1 OFF ON Start s top the operat ion 2 TEM P Select the desire d tempe rature 3 Qu ICk gu IDE Rem ote Cont rol Prep arati on 1 Remo ve the batter y cover 2 Insert AAA or R03 batter ...

Page 2: ...Panasonic Air Conditioner NOTE The illustrations in this manual are for explanation purposes only and may differ from the actual unit They are subjected to change without notice for future improvement OPERATION CONDITION Use this air conditioner under the following temperature range Temperature C Indoor Outdoor DBT WBT DBT WBT COOLING Max 32 23 46 26 Min 16 11 16 11 HEATING Max 30 24 18 Min 16 5 6...

Page 3: ...akage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and injury etc Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or ...

Page 4: ...me New batteries of the same type must be inserted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING POWER SUPPLY If the supply cord is damage it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard It is strongly recommended to be installed with Earth Leakage Circuit ...

Page 5: ...L mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation 4 TO SELECT FAN SPEED 5 OPTIONS FAN SPEED For AUTO the indoor fan speed is automatically adjusted according to the operation mode Maximum distances 8m 5 TO ADJUST AIRFLOW D...

Page 6: ... be set while the air conditioner is in operation DELAY ON AND OFF TIMER For example to start the air conditioner 7 hours later and stop 10 hours later 1 To select the Delay ON and OFF Timer press the button twice repeatedly 2 Press the button to select the delay hour for ON Timer 3 Press the button to select the delay hour for OFF Timer This mode of timer can only be set while the air conditioner...

Page 7: ...ntil 1 beep is heard then release Cooling Press and hold until 1 beep is heard then release Press again until 2 beeps then release Heating Press the button to turn off 8 AIR FILTERS Clean the filters regularly Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under the shade away from fire or direct sunlight Replace any damage filter 9 ANTI B...

Page 8: ...F during operation The unit is in Demand Response Mode Cracking sound during operation Changes of temperature cause the expansion contraction of the unit Check the following before calling for servicing SYMPTOM CHECK Heating Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and ...

Page 9: ...vents Use Auto OFF ON button to select Cooling Heating operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents Cooling 8 C Heating 14 C NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions Abnormal noise during operation Water foreign particles have enter...

Page 10: ...ting Capacity kW 3 30 3 30 4 25 4 25 Noise Level JIS C 9612 70 dB A dB A 42 42 42 42 Conditions 1m Distance Max cooling 47 48 48 50 Sound power level dB A 58 58 58 58 63 64 64 66 Air Circulation m3 min 12 4 12 1 12 7 12 4 Product Weight kg 8 0 8 0 25 27 Dimensions H W D mm 290 848 213 290 848 213 540 780 289 540 780 289 1 Standard piping length 5m Indoor Unit piping length is not included 2 Air fi...

Page 11: ... k محصول فنی مشخصات مدل داخلی واحد خارجی واحد جریان توان کننده سرد سرمایش ظرفیت گرمایش ظرفیت نویز میزان فاصله متر 1 شرایط سرمایش حداکثر نویز میزان هوا گردش محصول وزن ابعاد F568478_cover indd 23 2012 5 28 16 45 28 ...

Page 12: ...esired mode 1 OFF ON Start stop the operation 2 TEMP Select the desired temperature 3 QUICK GUIDE Remote Control Preparation 1 Remove the battery cover 2 Insert AAA or R03 batteries can be used 1 year 3 Close the cover 2 1 3 2 1 3 F568478_cover indd 24 2012 5 28 16 45 31 ...

Reviews: