CAUTION

INDOOR UNIT AND OUTDOOR UNIT

Do not wash the indoor unit with water, 

benzene, thinner or scouring powder to avoid 

damage or corrosion at the unit.
Do not use for preservation of precise equipment, 

food, animals, plants, artwork or other objects. 

This may cause quality deterioration, etc.
Do not use any combustible equipment in front 

of the airflow outlet to avoid fire propagation.
Do not expose plants or pet directly to airflow to 

avoid injury, etc.

Do not touch the sharp aluminium fin, 

sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 

the floor. After waxing, aerate the room properly 

before operating the unit.
Do not install the unit in oily and smoky areas to 

prevent damage to the unit.
Do not dismantle the unit for cleaning purpose 

to avoid injury.
Do not step onto unstable bench when cleaning 

the unit to avoid injury.
Do not place vase or water container on the 

unit. Water may enter the unit and degrade the 

insulation. This may cause an electric shock.
Do not open window or door for long time during 

COOL mode operation.
Ensure drainage pipe is connected properly and 

keep drainage outlet clear of gutters, containers 

or does not immersed in water to prevent water 

leakage.
After a long period of use or use with any 

combustible equipment, aerate the room 

regularly.
After a long period of use, make sure the 

installation rack is not deteriorate to prevent the 

unit from falling down.

REMOTE CONTROL

Do not use rechargeable (Ni-Cd) batteries.

It may damage the remote control.

To prevent malfunction or damage of the remote 

control:

•  Remove the batteries if the unit is not going to 

be used for a long period of time. 

•  New batteries of the same type must be 

inserted following the polarity stated. 

POWER SUPPLY

Do not pull the cord to disconnect the plug to 

prevent electric shock.

 

WARNING

POWER SUPPLY

If the supply cord is damage, it must be 

replaced by the manufacturer, its service agent 

or similarly qualified persons in order to avoid 

a hazard.
It is strongly recommended to be installed 

with Earth Leakage Circuit Breaker (ELCB) 

or Residual Current Device (RCD) to prevent 

electric shock or fire.
To prevent overheating, fire or electric shock:

• Insert the power plug properly.

•  Dust on the power plug should be periodically 

wiped with a dry cloth.

Stop using the product if any abnormality/failure 

occurs and disconnect the power plug or turn off 

the power switch and breaker.

(Risk of smoke/fire/electric shock)

Examples of abnormality/failure

•  The ELCB trips frequently. 

•  Burning smell is observed.

•  Abnormal noise or vibration of the unit is 

observed.

•  Water leaks from the indoor unit. 

•  Power cord or plug becomes abnormally hot.

•  Fan speed cannot be controlled.

•  The unit stops running immediately even if it is 

switched on for operation.

•  The fan does not stop even if the operation is 

stopped.

Contact your local dealer immediately for 

maintenance/repair.

Replacement or installation of power plugs shall 

be performed by authorized/qualified personnel 

only. The wires in this mains lead are coloured 

in accordance with the following code:

Wiring colour may vary depending on a country 

wiring code’s standard.
This equipment must be earthed to prevent 

electric shock or fire.

Prevent electric shock by switching off the 

power supply and unplug when:

- Before cleaning or servicing.

- Extended non-use.

- Abnormally strong lightning activity.

Black

earth

Terminals

Red

colours (IEC Standard)

Wires

live

brown
blue

green-yellow

neutral

Green/Yellow

F568478_EN_CS5.indd   16

2012-5-28   16:34:32

Summary of Contents for CS-RE12NKR

Page 1: ...KR CS RE12NKR CU RE12NKR Operating Instructions Air Conditioner Indoor Unit Outdoor Unit CS RE9NKR CU RE9NKR CS RE12NKR CCU RE12NKR Print ed in China F568 478 F120 4 00 MOD E AUTO HEAT DRY COO L Select the desire d mode 1 OFF ON Start s top the operat ion 2 TEM P Select the desire d tempe rature 3 Qu ICk gu IDE Rem ote Cont rol Prep arati on 1 Remo ve the batter y cover 2 Insert AAA or R03 batter ...

Page 2: ...Panasonic Air Conditioner NOTE The illustrations in this manual are for explanation purposes only and may differ from the actual unit They are subjected to change without notice for future improvement OPERATION CONDITION Use this air conditioner under the following temperature range Temperature C Indoor Outdoor DBT WBT DBT WBT COOLING Max 32 23 46 26 Min 16 11 16 11 HEATING Max 30 24 18 Min 16 5 6...

Page 3: ...akage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and injury etc Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or ...

Page 4: ...me New batteries of the same type must be inserted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING POWER SUPPLY If the supply cord is damage it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard It is strongly recommended to be installed with Earth Leakage Circuit ...

Page 5: ...L mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation 4 TO SELECT FAN SPEED 5 OPTIONS FAN SPEED For AUTO the indoor fan speed is automatically adjusted according to the operation mode Maximum distances 8m 5 TO ADJUST AIRFLOW D...

Page 6: ... be set while the air conditioner is in operation DELAY ON AND OFF TIMER For example to start the air conditioner 7 hours later and stop 10 hours later 1 To select the Delay ON and OFF Timer press the button twice repeatedly 2 Press the button to select the delay hour for ON Timer 3 Press the button to select the delay hour for OFF Timer This mode of timer can only be set while the air conditioner...

Page 7: ...ntil 1 beep is heard then release Cooling Press and hold until 1 beep is heard then release Press again until 2 beeps then release Heating Press the button to turn off 8 AIR FILTERS Clean the filters regularly Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under the shade away from fire or direct sunlight Replace any damage filter 9 ANTI B...

Page 8: ...F during operation The unit is in Demand Response Mode Cracking sound during operation Changes of temperature cause the expansion contraction of the unit Check the following before calling for servicing SYMPTOM CHECK Heating Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and ...

Page 9: ...vents Use Auto OFF ON button to select Cooling Heating operation After 15 minutes of operation it is normal to have the following temperature difference between air inlet and air outlet vents Cooling 8 C Heating 14 C NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions Abnormal noise during operation Water foreign particles have enter...

Page 10: ...ting Capacity kW 3 30 3 30 4 25 4 25 Noise Level JIS C 9612 70 dB A dB A 42 42 42 42 Conditions 1m Distance Max cooling 47 48 48 50 Sound power level dB A 58 58 58 58 63 64 64 66 Air Circulation m3 min 12 4 12 1 12 7 12 4 Product Weight kg 8 0 8 0 25 27 Dimensions H W D mm 290 848 213 290 848 213 540 780 289 540 780 289 1 Standard piping length 5m Indoor Unit piping length is not included 2 Air fi...

Page 11: ... k محصول فنی مشخصات مدل داخلی واحد خارجی واحد جریان توان کننده سرد سرمایش ظرفیت گرمایش ظرفیت نویز میزان فاصله متر 1 شرایط سرمایش حداکثر نویز میزان هوا گردش محصول وزن ابعاد F568478_cover indd 23 2012 5 28 16 45 28 ...

Page 12: ...esired mode 1 OFF ON Start stop the operation 2 TEMP Select the desired temperature 3 QUICK GUIDE Remote Control Preparation 1 Remove the battery cover 2 Insert AAA or R03 batteries can be used 1 year 3 Close the cover 2 1 3 2 1 3 F568478_cover indd 24 2012 5 28 16 45 31 ...

Reviews: