![Panasonic CS-PE12DKE Service Manual Download Page 22](http://html.mh-extra.com/html/panasonic/cs-pe12dke/cs-pe12dke_service-manual_1507911022.webp)
Heat Operation
Protection Operation
Forced Heat
Other
than
above
Mini-
mum
Con-
trol
Me
Shi
Lo-
Mode judging in Auto Operation
Preparing Operation of Timer-ON operation
Hot Start
Deice Control
Low Temperature Control
Maximum
Control
Relay OFF(Comp OFF)
Indoor Piping Temp Control(Auto Fan)
Other
than
above
Detection of
Timer-ON
Operation
Other than
above
Auto Fan Speed
Manual Fan Speed
Auto Fan Speed
Manual Fan Speed
Stop
Stop
SSHi
SLo- or SSLo
Refer to the following contents
Lo
Setting On Remote Control
Auto
Setting On Remote Control
Auto Fan Speed for Cooling Operation
a
b
c
d
e
f
g
h
a
b
No.C
No.B
No.A
Auto Fan Speed for Heating Operation
Refer to Piping Temperature Control.
Following eight patterns repeat over and over for auto fan speed. Each pattern persists ten
second.
Temp. Of outdoor unit under 35
Temp. Of outdoor unit above 35
PE9DKE
PE12DKE
No.A
No.B
No.C
970
990
950
1070
1090
1050
PE9DKE
PE12DKE
No.A
No.B
No.C
1130
1150
1110
1220
1240
1200
UNIT: rpm
CS-PE9DKE / CU-PE9DKE / CS-PE12DKE / CU-PE12DKE
22