![Panasonic CS-PC12QKH Service Manual Download Page 51](http://html.mh-extra.com/html/panasonic/cs-pc12qkh/cs-pc12qkh_service-manual_1507892051.webp)
51
12.2.4 Connect the Cable to the Indoor
Unit
1 The inside and outside connection cable can
be connected without removing the front grille.
2
Connecting cable
between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 4 x 1.5 mm
2
flexible
cord, type designation 60245 IEC 57 or
heavier cord. Do not use joint connection
cable. Replace the wire if the existing wire
(from concealed wiring, or otherwise) is too
short.
Secure the connection cable onto the control board with the holder.
Note:
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.
Summary of Contents for CS-PC12QKH
Page 16: ...16 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 17: ...17 5 Dimensions 5 1 Indoor Unit 5 1 1 CS PC9QKH CS PC12QKH ...
Page 18: ...18 5 1 2 CS PC18QKH CS PC24QKH CS PC28QKH ...
Page 19: ...19 5 2 Outdoor Unit 5 2 1 CU PC9QKH CU PC12QKH 5 2 2 CU PC18QKH ...
Page 20: ...20 5 2 3 CU PC24QKH 5 2 4 CU PC28QKH ...
Page 21: ...21 6 Refrigeration Cycle Diagram ...
Page 22: ...22 7 Block Diagram 7 1 CS PC9QKH CU PC9QKH CS PC12QKH CU PC12QKH CS PC18QKH CU PC18QKH ...
Page 23: ...23 7 2 CS PC24QKH CU PC24QKH ...
Page 24: ...24 7 3 CS PC28QKH CU PC28QKH ...
Page 29: ...29 9 Electronic Circuit Diagram 9 1 CS PC9QKH CU PC9QKH CS PC12QKH CU PC12QKH ...
Page 30: ...30 9 2 CS PC18QKH CU PC18QKH ...
Page 31: ...31 9 3 CS PC24QKH CU PC24QKH ...
Page 32: ...32 9 4 CS PC28QKH CU PC28QKH ...
Page 34: ...34 10 1 1 2 CS PC18QKH ...
Page 35: ...35 10 1 1 3 CS PC24QKH ...
Page 36: ...36 10 1 1 4 CS PC28QKH ...
Page 52: ...52 12 2 5 Wire Stripping and Connecting Requirement ...
Page 58: ...58 13 1 2 Cooling Operation Time Diagram For PC18 24 28QKH ...
Page 60: ...60 13 2 2 Soft Dry Operation Time Diagram For PC18 24 28QKH ...
Page 73: ...73 17 1 1 3 To Remove Discharge Grille ...
Page 74: ...74 17 1 1 4 To Remove Control Board 17 1 1 5 To Remove Cross Flow Fan and Indoor Fan Motor ...
Page 75: ...75 ...
Page 77: ...77 17 2 1 3 To Remove Main Electronic Controller Fig 3 ...
Page 78: ...78 17 2 1 4 To Remove Discharge Grille Fig 6 17 2 1 5 To Remove Control Board Fig 7 ...
Page 79: ...79 17 2 1 6 To Remove Cross Flow Fan and Indoor Fan Motor Fig 8 Fig 9 ...
Page 80: ...80 Fig 10 Fig 11 ...
Page 81: ...81 18 Technical Data 18 1 Thermostat Characteristics Cooling Soft Dry ...